ND-45669 (E)
CHAPTER 3
Page 347
Revision 2.0
CME0
COMMAND CODE
TITLE:
INITIALIZATION
E0
4.
DATA TABLE:
Note:
For the Data “MMDDHHMM”, enter the Month, Date, and Time (hour and minute) of the time, as shown below.
MM :
Month
(01 (Jan.) – 12 (Dec.))
DD :
Date
(01 – 31)
HH :
Hour
(00 – 24)
MM :
Minute
(00 – 59)
1.
FUNCTION:
This command allows the maintenance personnel to reset the system with the CAT.
2.
PRECAUTION:
If the setting data (Month, Day and Time) is different from the current time of the system clock (set by
command 02), any request to initialize the system is not accepted and “DATA ERROR” is displayed.
3.
ASSIGNMENT PROCEDURE:
Y
TYPE OF INITIALIZATION
SETTING DATA
RELATED
COMMAND
No.
MEANING
No.
MEANING
DATA
MEANING
2
System Initialization
2000
MP Reset
MM
DD
HH
MM
Note
Current time dis-
played on Multiline
Terminal/SN610
ATTCON
5
Desired FP/AP
Initialization
00
15
FP/AP Number 00
FP/AP Number 15
To request the ini-
tialization immedi-
ately.
CM02
CM05
ST + E0Y + DE +
TYPE OF INITIALIZATION
(2 - 4 digits)
+ DE +
DATA
(8 digits)
+ EXE
~
~
[CME0]
Initialization
Summary of Contents for NEAX 2000 IVS
Page 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Page 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Page 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Page 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...