![NEC NEAX 2000 IVS Command Manual Download Page 333](http://html.mh-extra.com/html/nec/neax-2000-ivs/neax-2000-ivs_command-manual_250034333.webp)
CHAPTER 3
ND-45669 (E)
Page 296
Revision 2.0
CM90
COMMAND CODE
TITLE:
MULTILINE TERMINAL/SN610 ATTCON/ADD-ON MODULE KEY ASSIGNMENT
90
MAT
• ATTCON Multi-Function Keys
YY
No.
ATTCON
STATUS
No.
MEANING
SETTING
DATA
FUNCTION
REMARKS
RELATED
COMMAND
00
00
(Idle State)
Idle State
F6100
Room Cut Off
(RCOF)
F6102
Do Not Disturb
(DND)
F6104
Reset (RESET)
F6110
Mode (MODE)
F6111
Programming
(PROG)
DISA, System
Speed Dialing,
Date and Time
and Tone Ringer
01
(ANS &
ORG)
When answering
or originating
F6105
Serial Call Set (SC)
CM90-F6062
F6106
Flash over trunk
(CAS, Centrex)
(SHF)
CM05
YY=16, 86
CM41 Y=2
Function No. 17
F6112
Out pulse (PB
signal) short (SPB)
CM35 YY=26
F6113
Out pulse (PB
signal) long (LPB)
CM41 Y=0
Function No. 14
F6203
Talk (TALK)
02
(STA busy)
When the called
station is busy
F6107
Busy Verification
(BV)
Attendant Override
CM08-012
CM15 YY=09
03
(STA DND)
When the called
station is in DND
F6108
Do Not Disturb
Override (DDOV)
Summary of Contents for NEAX 2000 IVS
Page 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Page 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Page 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Page 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...