CHAPTER 3
ND-45669 (E)
Page 100
Revision 2.0
CM12
COMMAND CODE
TITLE:
STATION CLASS-1
12
MAT
4.
DATA TABLE:
3.
ASSIGNMENT PROCEDURE:
:
Initial Data
YY
SETTING DATA
No.
MEANING
DATA
MEANING
00
(PB/DP)
DTMF or DP
(This data setting is not
required for a Multiline
Terminal)
1
2
3
DP
DTMF
DP / DTMF
01
(RSCA
RSCB)
Trunk Restriction
Class
XX
Contents of Day/Night Trunk Restriction Class
02
(SFCA
SFCB)
Service Restriction Class
A•B
XXXX
Note:
The features available in each class are
programmed in CM15 YY = 00-49, YY = 53-73.
ST + 12YY + DE +
STATION
No.
(1-4 digits)
Automatic/
Manual/
Dial Intercom
No. (4 digits)
Loop
Line No.
(4 digits)
ICI/OPR
Line No.
(4 digits)
+ DE +
+ EXE
DATA
(1-4 digits)
11
Day Trunk Restriction Class
X
X
Night Trunk Restriction Class
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCD)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
Restriction of
Connection Trunk:
CM35
YY=51-58
YY=61-68
Toll Restriction:
CM81, CM8A
1515
XX
Service Restriction Class B
(00-15)
XX
Service Restriction Class A
(00-15)
Summary of Contents for NEAX 2000 IVS
Page 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Page 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Page 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Page 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...