ND-45669 (E)
CHAPTER 3
Addendum-002
Page 203
JANUARY, 1999
Revision 2.2
CM44
COMMAND CODE
TITLE:
EXTERNAL EQUIPMENT STARTING CONDITIONS
44
4.
DATA TABLE:
1.
FUNCTION:
This command assigns the relay (circuit number of the PN-DK00) used for controlling external equip-
ment.
2.
PRECAUTION:
None
3.
ASSIGNMENT PROCEDURE:
CIRCUIT NUMBER
RELATED
COMMAND
REMARKS
NUMBER
MEANING
XXX
XX
X
Circuit Number
(0-3)
Card Number
(00-31)
CM10
Card number E8XX
CIRCUIT
ST + 44 + DE + DE +
+
+ EXE
(3 digits)
DATA 1
(2 digits)
DATA 2
(2 digits)
[CM44]