CHAPTER 3
ND-45669 (E)
Page 294
Revision 2.0
CM90
COMMAND CODE
TITLE:
MULTILINE TERMINAL/SN610 ATTCON/ADD-ON MODULE KEY ASSIGNMENT
90
MAT
• ATTCON Function Keys
YY
SETTING
DATA
FUNCTION
STANDARD
KEY
SETTING
REMARKS
RELATED
COMMAND
No.
MEANING
00
(Key
data)
Setting of
Function
F6100
Room Cut Off (RC)
For Hotel ATTCON
Note 1
F6101
Message Waiting (MW)
F6102
Do Not Disturb (DND)
F6103
Wake Up/Do Not Disturb
Override (WU/OV)
F6104
Reset (RESET)
F6105
Serial Call Set (SC)
CM90-F6062
F6106
Flash over trunk (CAS)
(SHF)
CM35
YY=16
F6107
Busy Verification (BV)
CM08-012
CM15
YY=09
F6108
Do Not Disturb Override
(DNDOV)
For Hotel ATTCON
Note 2
F6109
Wake Up (WU)
F6110
Note 3
Mode (MODE)
Day/Night
mode change,
ATT lockout
F6111
Programming (PROG)
System Speed
Dialing
Date and Time
Tone Ringer
Choice of
Night Service
F6112
Out pulse (PB signal) short
(SPB)
CM35
YY=26
F6113
Out pulse (PB signal) long
(LPB)
CM41 Y=0
Function
No. 14
Note 1:
Use the ANSWER key as the SET key for Hotel features.
Note 2:
Do not assign this data to key numbers 1 to 6.
Note 3:
For SN716 DESKCON, this data is not required.
Summary of Contents for NEAX 2000 IVS
Page 1: ...ND 45669 E ISSUE 2 PART OF STOCK 151901 Command Manual DECEMBER 1997 NECAmerica Inc ...
Page 17: ...CHAPTER 1 ND 45669 E Page 2 Revision 2 0 This page is for your notes ...
Page 77: ...CHAPTER 2 ND 45669 E Page 60 Revision 2 0 This page is for your notes ...
Page 473: ...CHAPTER 4 ND 45669 E Page 430 Revision 2 0 This page is for your notes ...