![NEC NEAX 2000 IVS Command Manual Download Page 356](http://html.mh-extra.com/html/nec/neax-2000-ivs/neax-2000-ivs_command-manual_250034356.webp)
ND-45669 (E)
CHAPTER 3
Page 317
Revision 2.0
CMA6
COMMAND CODE
TITLE:
ATTRIBUTE DATA FOR RS-232C PORT ON AP01
A6
MAT
4.
DATA TABLE:
1.
FUNCTION:
This command is used to assign the attribute data for the RS-232C port on the PN-AP01 card.
2.
PRECAUTION:
None
3.
ASSIGNMENT PROCEDURE:
:
Initial Data
YY
SETTING DATA
RECOMMENDED
SETTING
No.
MEANING
DATA
MEANING
04
Data Transmission Speed of
RS-232C Port
0
1
2
3
4
5
6
150 bps
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps
5
(example)
05
Parity Check
0
1
Effective
Ineffective
1
06
Synchronous/Asynchronous
0
3
7
Synchronous Transmission by
Internal
Synchronous Transmission by
External
Asynchronous
7
07
Duplex or half-duplex
0
1
Half-duplex
Duplex
1
ST + A6YY + DE + 3 +
DATA
(1 - 2 digits)
+ EXE
[CMA6]