background image

 

                                     

 

 

 

 
 

Manual GX300 
 

 
 

          

 

 
 
 
 

 

 

                                                                                                                  

IDEX India Pvt. Ltd. 

                                                                                               Survey no: 256, GIDC Manjusar  
                                                                                                      

Savli,  Dist.: Vadodara 

                                                                                                                       391 770

,  

I n d i a

                                                 

 

                

 

       

V 7.0   29

10

‐202

1

 

 

Summary of Contents for GX300

Page 1: ...1 Manual GX300 IDEX India Pvt Ltd Survey no 256 GIDC Manjusar Savli Dist Vadodara 391 770 India V 7 0 29 10 2021...

Page 2: ...f Fast Fluid Management B V to notify any person of such revision or change Details and values given in this manual are average values and have been compiled with care They are not binding however and...

Page 3: ...3 2 1 Turning on the machine if the cradle is in the correct position 12 3 2 2 Turning on the machine if the cradle is not in the correct position 12 3 2 3 Turning on the machine when the machine is...

Page 4: ...e the machine to final location 22 4 3 2 Level the machine 22 4 4 Finish the installation 23 5 Troubleshooting 24 5 1 General troubleshooting procedure 24 5 2 Opening solenoid lock manually 24 5 3 Con...

Page 5: ...ize yourself with the structure and content 2 To read the safety chapter in detail and make sure you understand all the instructions See chapter 2 3 To carry out the actions completely and in the give...

Page 6: ...use extension cords or inadequately rated power cables Make sure that the power cable is freely accessible Do not place objects on top of the machine Keep lids panels and covers closed and in place w...

Page 7: ...explosion risks 2 3 User qualification for installation Only install the machine when you are a qualified service technician who is trained and certified by Fast Fluid Management B V 2 4 Safety symbol...

Page 8: ...rd CAUTION Can cause damage to the machine Note Shows further information 2 7 Disposal of the machine 1 Sort the machine the accessories and the packaging for environmentally friendly recycling 2 Do n...

Page 9: ...ator manual 3 1 Description 3 1 1 Overview of the machine A Can Plate Top E Emergency Switch I Drain Orifice B Can Plate Bottom F Control Panel J Can Table C Door G Casing K Net Entry D Top Cover H Ad...

Page 10: ...e multiple functions of the program keys 3 1 3 Overview of the program keys Ready for use When the machine is ready for use the display shows the available programs A T1 key mix time 1 D Program key B...

Page 11: ...11 Operator manual GX300 Choose the mix time Key pushed Mix time s T1 60 T2 120 T3 180 Note The table shows the default values...

Page 12: ...switch is released 3 Set the Main switch to ON When the machine is on you hear two beeps When the machine is operational the display shows RDY 3 2 2 Turning on the machine if the cradle is not in the...

Page 13: ...ws one dot 1 Push any key to unlock the door When the machine is operational the display shows RDY 3 2 4 General mixing procedure 1 Place the can See 3 2 5 2 Start the machine See 3 2 6 Note The machi...

Page 14: ...possible that the can is heavy Use the correct lifting tool when appropriate Obey the local regulations CAUTION For multiple can mixing Make sure that all cans have the same height Do not stack cans...

Page 15: ...e that the can handles cannot move Use a can handle retainer for example self adhesive tape Put back the can table 1 Pull up the handle A to unlock the can table 2 Push the can table B inwards until y...

Page 16: ...can plates manually Move the can plates manually when the door is closed 1 Examine how much space is needed between the can plates 2 If 0 4 cm extra space is needed a Push the stop up key The can pla...

Page 17: ...e 3 2 7 3 2 12 Using the emergency stop switch 1 Push the emergency stop switch A The machine stops immediately CAUTION Only push the emergency stop switch in case of a safety emergency Do not use the...

Page 18: ...C Lead Screw D Bevel gear E Pinion gear Recommend to use thick grease like SKF VKG 9 0 5 3 3 4 Periodic maintenance monthly 1 Remove all spilled paint from the machine Refer to 3 4 2 Remove all dirty...

Page 19: ...stallation GX300 4 Installation 4 1 Unpack the machine 4 1 1 Remove the cardboard 1 Remove the tensioning straps A 2 Remove the cardboard B 4 1 2 Remove the protection and foil 1 Remove the plastic fo...

Page 20: ...Remove the transport brackets B 4 2 Put the machine in position 4 2 1 Put the machine in position 1 Loosen the nuts C of the adjustable feet B 2 Move up the adjustable feet until the wheels A are on...

Page 21: ...21 Installation GX300 4 2 2 Make a ramp of the pallet 1 Remove the screws 2 Remove the pallet beam 4 2 3 Move the machine from the pallet 1 Move the machine 2 Roll the machine on the floor B B...

Page 22: ...is well lit and well ventilated Note Make sure that the power cable and main switch are freely accessible 1 Push the machine to the final location 2 Connect the power cable to the net entry 3 Connect...

Page 23: ...23 Installation GX300 4 4 Finish the installation 1 Turn on the machine See 3 2 1...

Page 24: ...time pull the door slightly Repeat the same procedure for bottom lock door will be fully open Option2 Holes are provided in front panels at top and bottom side where solenoids locks positioned To acc...

Page 25: ...is blocked Push the Stop Up key The display shows E38 No Encoder is detected Restart the machine See 3 2 13 The display shows E39 No Clamp Current Restart the machine See 3 2 13 The display shows E47...

Page 26: ...oting GX300 5 4 4 Software errors Problem Possible cause Possible solution The display shows F00 Parameter is not available Contact service See 5 3 The display shows F54 Invalid state value Contact se...

Page 27: ...sions height x width x depth cm 101 x 82 x 87 Dimensions for Installation height x width x depth cm 101 x 82 x 84 Packed dimensions height x width x depth cm 118 x 88 x 98 Net weight of the machine kg...

Page 28: ...cation 32 EMC ElectroMagnetic Compliancy classification Class B Overvoltage category Class II 6 6 Electrical specifications Parameter Specification Power consumption maximum W 1000 Maximum leakage cur...

Page 29: ...Technical data GX300 6 7 Electrical Diagram 29...