Upgrading Your Server 9-15
Notes on Replacing Hard Disk Drives in the RAID System
When the hard disk drives are in the RAID System, you can restore the state before an error using
the auto-rebuild feature that stores the data in the old hard disk drive into a new one.
The auto-rebuild feature is available for the RAID 1, RAID5, or RAID6.
Auto-rebuild is carried out when you hot-swap a failed hard disk drive with a new one (replace the
disk while the server is powered). While auto-rebuild is in progress, the DISK LED flashes green
and amber alternatively to indicate it.
IMPORTANT:
When auto-rebuild fails, the DISK LED lights in amber. Remove
and install the hard disk drive again to restart auto-rebuild.
If the RAID System management utility is installed, it may display
or act as follows. If the DISK LED does not light in amber after
auto-rebuild, however, auto-rebuild has completed successfully.
– Displays "Rebuild was cancelled" on the screen while auto-
rebuild is in progress.
– Appears to stop and restart auto-rebuild.
Observe the following notes for auto-rebuild.
Do not power off the server in the period between a hard disk drive error and completion
of auto-rebuild.
When you removed a hard disk drive, wait at least 90 seconds before installing the hard
disk drive back again.
Do not replace another hard disk drive while rebuilding is in progress. (The DISK LED
flashes in green and amber alternatively while rebuilding the hard disk drive.)
Summary of Contents for Express5800/120Rj-2
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Notes on Using Your Server 1 3 Internal View ...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 90: ...3 24 Setting Up Your Server This page is intentionally left blank ...
Page 164: ...4 74 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 172: ...4 82 Configuring Your Server This page is intentionally left blank ...
Page 240: ...7 12 Maintenance This page is intentionally left blank ...
Page 354: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Page 364: ...C 2 IRQ This page is intentionally left blank ...
Page 412: ...E 24 Installing Windows Server 2003 This page is intentionally left blank ...
Page 414: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Page 418: ...G 4 Product Configuration Record Table This page is intentionally left blank ...