8-4 Troubleshooting
POST Error Messages
When POST detects an error, it displays an error message on the display unit screen. The following
table lists error messages and actions to take.
IMPORTANT:
Take a note on the messages displayed before
consulting with your service representative. Alarm messages are useful
information for maintenance.
Error
code
Error message
Recommended Action
0200
Failure Fixed Disk.
Contact your service representative.
0210
Stuck Key.
Disconnect the keyboard and connect it
again.
0211
Keyboard error
Disconnect the keyboard and connect it
again. If the error cannot be corrected,
contact your service representative.
0213
Keyboard locked - Unlock key switch.
Release the lock of the key switch. If the
error cannot be corrected in spite of the
release of the lock, contact your service
representative.
0220
Monitor type does not match CMOS - Run
SETUP.
Start the SETUP. If the error cannot be
corrected in spite of the start of SETUP,
contact your service representative.
0230
System RAM Failed at offset.
0231
Shadow Ram Failed at offset.
0232
Extended RAM Failed at address line.
Contact your service representative.
0250
System battery is dead - Replace and run
SETUP.
Contact your service representative to
replace the battery. (After restarting the
computer, start the SETUP to provide the
setting again.)
0251
System CMOS checksum bad - Default
configuration used.
The default values have just been set. Start
the SETUP to provide the setting again. If
the error cannot be corrected, contact your
service representative.
0252
Password checksum bad - Passwords
cleared.
The password has just been cleared. Start
the SETUP to provide the setting again.
0260
System timer error.
0270
Real time clock error.
0271
Check date and time setting.
Start the SETUP to set the date and time
again. If the same error occurs
successively in spite of the resetting,
contact your service representative.
0280
Previous boot incomplete - Default
configuration used.
Start the SETUP to provide the setting
again.
0281
Memory size found by POST differed from
EISA CMOS.
Initialize EISA CMOS.
02D0
System cache error - Cache disabled.
The cache cannot be used. Contact your
service representative.
Summary of Contents for Express5800/120Rj-2
Page 16: ...x This page is intentionally left blank ...
Page 19: ...Notes on Using Your Server 1 3 Internal View ...
Page 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Page 90: ...3 24 Setting Up Your Server This page is intentionally left blank ...
Page 164: ...4 74 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Page 172: ...4 82 Configuring Your Server This page is intentionally left blank ...
Page 240: ...7 12 Maintenance This page is intentionally left blank ...
Page 354: ...9 78 Upgrading Your Server This page is intentionally left blank ...