1. Installing Internal Optional Devices
Express5800/R120h-1M User’s Guide
55
Chapter 2 Preparations
4.
Remove the primary PCI riser cage.
5.
Match the TPM kit with the connector grooves on the motherboard. Press the connector in firmly and install
the TPM kit. Please check the location of the TPM connector on the motherboard by looking at the quick
reference level attached to the back of the top cover.
Note
If you try to remove the already attached TPM from the motherboard you may
cause injury to the TPM cover, TPM, and motherboard. If it was installed on a
different device, the data (including the key) stored in TPM are deleted when the
power is turned on. the TPM that has been removed from the original server and
installed on another server.
6.
Install the TPM cover
(1) Align the holes and locking latches on both sides of the TPM connector.
(2) Press down the center of the cover firm and straight until you hear a locking sound.
7.
Re-attach the options and cables that were removed in step 3.
8. See
Chapter 2 (1.26 Installing Top Cover)
to attach the top cover of the server.
Note
In order to prevent damage of the system due to improper cooling or elevated
temperature, please do not activate the server or enclosure without implementing
any of component or blank on all of drive bays and device bays.