ALL PLENUM DUCTING AND VENTING INSTALLATION MUST CONFORM WITH CAN/CSA B365-
01, CSA B139-09, AND NFPA 211. ALWAYS CHECK LOCAL BUILDING AND FIRE CODES , AND
AUTHORITIES HAVING JURISDICTION.
ALL PLENUM, DUCTING AND VENTING MUST BE INSTALLED BY A QUALIFIED/LICENSED
INSTALLER.
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR. DO NOT IMPEDE AIR MOVEMENT IN ZONES MARKED "CLEARANCE TO COMBUSTIBLES".
MINIMUM CLEARANCE TO COMBUSTIBLE DIMENSIONS MUST BE IMPLEMENTED.
•
stand alone wood furnace
•
combination wood/oil furnace
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE!!
THE WOOD FURNACE SECTION CAN OPERATE USING A MINIMUM 6" Ø FLUE PIPE, BUT WE
RECOMMEND THAT THE FLUE SIZE BE SET AT A MINIMUM OF 7" Ø WHERE THE FURNACE IS
TO BE SET UP AS (OR IN CONSIDERATION TO A FUTURE RETRO FIT TO A WOOD/OIL OR WOOD/
OIL/ELECTRIC COMBINATION. CHIMNEY MUST BE APPROVED FOR USE WITH WOODBURNING
APPLIANCES (2100°F).
VENTING CONFIGURATION FOR BRINGING SEPARATE WOOD AND OIL FURNACE FLUES INTO A COMMON VENT
1
2
3
4
11
10
9
8
7
6
5
12
1
2
3
4
10
9
8
7
6
5
11
12
Legend
(ITEMS 1 THROUGH 11 BY INSTALLER)
1.
Vent/chimney in accordance with CAN/
CSA-B365-01, CSA B139-09, NFPA211,
construction and installation by quali
fi
ed
licensed installer
2. 7"
T
3.
6" to 7" Increaser
4. 6"
T
5.
6" End cap for clean out
6.
5" to 7" Increaser
7.
90° 5" Elbow
8. Barometric
damper
9.
45° 5” Elbow (change angle to suit incline)
10. WARNING: Oil
fl
ue to be mounted on same
side of furnace as blower box, to respect
clearance to combustible dimensions.
11. 90° 5" Elbow (offset in two directions)
12. Heat
shield
LEFT HAND RA CONFIGURATION
RIGHT HAND RA CONFIGURATION
6.0 PLENUM AND VENTING INSTALLATION/
CLEARANCE TO COMBUSTIBLE MATERIALS
6.1 FLUE / CHIMNEY FOR HMF150 IN CONFIGURATIONS
6.2 VENTING CONFIGURATION FOR WOOD/OIL COMBINATION FURNACE
6.1.1 Controlling
Draft
• Use of inclined manual dampers are forbidden.
• Barometric dampers can be installed to maintain normal operating draft between 0.04” and 0.06” W.C
•
combination wood/electric furnace
•
combination wood/electric/oil furnace
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...