
W415-0910 / A / 09.16.10
3
1.0 VUE D'ENSEMBLE DE L'INSTALLATION
!
AVERTISSEMENT
CET APPAREIL ET SES COMPOSANTS SONT CONÇUS POUR ÊTRE INSTALLÉS ET FONCTIONNER
COMME UN SYSTÈME. TOUTES MODIFICATIONS OU SUBSTITUTIONS DE COMPOSANTS, AUTRES
QUE CELLES INDIQUÉES DANS LES INSTRUCTIONS D'INSTALLATION, AURONT POUR EFFET
D'ANNULER L'HOMOLOGATION OMNI ET RISQUE D'ANNULER LA GARANTIE. CELA PEUT AUSSI
CRÉER UNE INSTALLATION DANGEREUSE. LISEZ BIEN TOUTES LES INSTRUCTIONS AVANT DE
COMMENCER VOTRE INSTALLATION ET SUIVEZ-LES À LA LETTRE.
ÉCHANGEUR DE
CHALEUR
(Section 9.8.1)
MODULE DE LA
SOUFFLERIE
(Section 5.2)
REGISTRE DE DÉRIVATION
(Section 8.5)
MODULE DE LA
FOURNAISE ÉLECTRIQUE
(Section 5.4)
PIÈCES DE RECHANGE POUR PORTE
(Section 9.6, 9.7)
MODULE DE LA FOURNAISE
À L’HUILE (Section 5.3)
BASE DE PROTECTION
(Section 6.6)
CHAMBRE DE COMBUSTION
À COMBUSTIBLE SOLIDE (Section 4.7)
INFORMATION SUR LA PLAQUE
D’HOMOLOGATION (Section 2.4)
CONTRÔLE DE COMBUSTION
(Section 4.6)
AIR COMBURANT EXTÉRIEUR
(Section 3.2)
INSTALLATION DE
LA CHEMINÉE (Section 6.0)
VUE D'ENSEMBLE DE L'INSTALLATION
W3
85-
04
13
HMF150
LIST
ED SO
LID
FU
EL
F
IRED
C
ENT
RA
L
FURNA
CE
TEST
ED T
O:
CA
N-
CSA
B
366-1
-M91
/ UL391
4th
Ed
20
06
(JUL
Y 200
8) /
UL
727 /
CSA
B
14
0.4 /
CS
A B
212
MOD
EL
: H
MF15
0
REP
OR
T N
O.:
_4
15
-S-09-2
_
CAUTION
:
HOT W
HILE IN
OPERA
TION. D
O
NOT
TO
UC
H. K
EEP
CH
ILD
REN,
CL
OTHIN
G AND
FURNI
TURE A
WA
Y.
CONT
ACT MA
Y CAUSE
SKI
N B
URNS
. SEE NA
MEPLA
TE AND
IN
ST
RUCTION
S.
TE
CHNICAL
DA
TA
BL
OWE
R /
VEN
TILA
TEU
R
1/
3 HP
ELECT
RIC
AL R
AT
ING
/
1
20
V, 1
0.3
AM
PS,
ALIM
EN
TAT
IO
N EL
ECT
RIQUE
60
Hz
EX
TERNA
L ST
ATIC PR
ESS
URE
/
0.2
” W
.C.
PRE
SS
ION
ST
ATI
QU
E E
XT
.
0.2”
C.E
.
DRAF
T PRESS
UR
E/
WO
OD
FL
UE:
MIN
. 0.4”
W
.C
OIL
FL
UE:
0.2
”W
.C.
OIL F
UR
NA
CE
- OIL F
IRING R
AT
E: 0
.66 GA
L US
- OIL
PR
ES
SU
RE:
120 PSI
- NOZZ
LE:
0
.65
- 60
°A
IN
STA
LLA
TION
- USE
ONL
Y I
N A
CC
ORDANC
E W
ITH
WOLF
STEEL
LT
D’S
INS
TRUCTI
ON
S.
CO
NTA
CT
LOCAL
BUILD
ING, F
IRE OFFIC
IAL
S AND
OT
HER
AG
ENCIE
S H
AVI
NG LOCA
JU
RI
SDICT
ION
ABO
UT
R
ES
TRIC
TIONS AND
INST
ALL
ATION INS
PECTION
IN
YOUR
AREA
.
CHIMNE
Y T
YP
E
: F
OR “
W
OOD
ON
LY” FURN
ACE
CONFI
GUR
AT
ION MI
NIMUM
6” (
15
2mm) DIA
METER
LISTED (
UL
103
HT)
RES
IDE
NTIA
L C
HI
MN
EY
. FO
R
“WOOD/O
IL
COM
BIN
ATION” F
URNA
CE
RECOMM
EN
DED M
INI
MUM 7”(1
78mm)
DI
AME
TE
R LIS
TED (UL
103
HT
) RE
SIDENTIAL
CH
IMNEY
.
DO
NO
T CONN
ECT
THI
S
UN
IT
TO
A
CHI
MNEY
FL
UE
SER
VI
NG
AN
OTH
ER AP
PL
IANC
E UNLE
SS
US
ING
IN
A “AD
D
ON”
CONF
IG
URA
TION
WI
TH
A
PRE
EX
IS
ITNG
OI
L
FURN
ACE -
SE
E MAN
UA
L U
ND
ER
PL
ENUM
AN
D IN
ST
ALLA
TION.
CHIMNEY
CONNEC
TO
R
: 6” (1
52mm)
DIAME
TER
MI
NIMU
M
24
GAUGE
STE
EL
MINIMUM
CLE
ARANCE
FRO
M HORIZ
ONT
AL
CON
NECT
OR
AND
CE
ILI
NG
18” (455mm
).
SP
ECIA
L M
ETH
ODS
AR
E
REQU
IRED
WHEN P
ASSING A
C
HIMNEY
TH
ROU
GH
A
WA
LL O
R CE
ILING
. S
EE INST
RUCTIONS
AND
BU
ILDING
CODES
.
DO NOT
OB
STRUCT
SP
ACE
UNDE
R
FUR
NACE
.
UNIT
C
AN BE I
NST
ALLE
D ON CO
MB
USTIB
LE S
URF
ACE
(W
OOD SUBSTRA
TE ONL
Y –
CA
RPET
AN
D O
THE
R F
LOO
R
COVERINGS
TO
BE R
EMOV
ED
) PROVID
ING
E
MBER
ST
OP
SH
IELD (SEE
MA
NUA
L)
INS
TALLE
D
BET
WEE
N
FU
RNA
CE A
ND
FLOOR
AND
MIN
IMU
M
1 ¼”
AIR
GAP
MAINT
AINE
D B
ETWE
EN
FUR
NA
CE A
ND
FLOO
R.
FUEL
: FOR
US
E WITH
SO
LID
W
OOD
FUEL
ON
LY
. DO
NO
T U
SE
GRA
TE
OR ELE
VAT
E F
IRE
. BUI
LD WOO
D F
IRE
D
IRECT
LY
O
N H
EAR
TH
.
AUTH
ORIZE
D MO
DULES
FO
R CON
NE
CTION
TO
HM
F150 FU
RN
ACE
:
BLOW
ER BOX MODU
LE -
HMF
K-BM
P33
ELECTRIC
FURNA
CE
MO
DU
LE -
HM
FK
-E
F20
OIL
FURNACE MO
DU
LES -
HM
FK-OFRF40
,
HM
FK-
OF
AFG
DHW PRE
HEA
T M
ODU
LE -
HMFK-
DHW
“ADD ON”
FU
RNACE MO
DULE -
HM
FK-AD
DON
THESE
ARE
THE O
NLY
AUTH
ORIZED
COMP
ONENTS
THA
T M
AY
BE A
TT
ACHED T
O TH
E HMF1
50
FURNACE A
SI
DE
FR
OM CONNE
CT
ION T
O
FOR
CED A
IR SYST
EM
RETURN
AND
SUPP
LY
PL
ENUM
S.
M
OD
ULE
S M
US
T BE
IN
ST
ALLED T
O
MANU
FAC
TURERS I
NSTRU
CTI
ONS P
OSTE
D IN
TH
E I
NST
ALLA
TIO
N/O
WNER
S
MANUA
L
ACCOMP
ANY
ING
HMF15
0 A
ND I
NSTRUC
TION
ADD
END
UMS INCL
UD
ED W
ITH
EACH MO
DULE
.
THE H
MF150 FU
RNAC
E IS C
ER
TIF
IED
FOR
SER
IES CO
NNECTI
ON
TO
TH
E SUP
PL
Y PL
ENUM OUT
LE
T ONL
Y OF
A G
AS F
IRED
, O
IL
FIR
ED,
OR E
LECTR
IC FURN
ACE
WH
EN
USED A
S AN
WO
OD FURNA
CE “A
DD-ON”
.
DO
NOT C
ONNE
CT
THI
S
FURN
ACE T
O
A CHIMNE
Y SE
RV
ICE
A G
AS F
UR
NA
CE.
DO NOT CONNECT DU
CTWO
RK SO T
HA
T RE
VERSE
FL
OW
IS
POSS
IBL
E.
DO NOT R
EL
OC
ATE O
R B
YP
ASS
AN
Y OF THE
SA
FETY
CONT
ROLS
IN
TH
E
OR
IGINAL
FURN
AC
E
INS
TA
LL
AT
IO
N (”ADD O
N” CON
FIGURA
TION
).
CAUT
IO
N:
THI
S AP
PL
IA
NC
E
MUST B
E I
NST
AL
LED
BY
A QUA
LIFIED
IN
ST
ALLE
R.
USE
OF
UN
AUT
HORIZE
D
CO
MP
ONENT
S O
R
FA
ILURE T
O COMP
LY
WITH
INST
ALL
AT
IO
N I
NS
TRU
CT
ION
S WILL
R
ESUL
T IN
V
OI
DED W
ARRA
NTY
.
WA
RNING
: RISK
OF
SM
OKE S
PIL
LAG
E. OPER
AT
E ONL
Y W
ITH
FIR
IN
G A
ND
AS
H R
EMO
VAL
DO
OR TIG
HTL
Y CL
OSED. DO
N
OT
OVERFIRE.
IF
HEA
TER
OR C
HI
MN
EY
CONNECT
ORS
GLOW
, YOU
ARE O
VERF
IRIN
G –
IMM
ED
IATEL
Y TUR
N O
FF THER
MO
ST
AT
A
ND
E
NSURE
PRIMAR
Y S
HUTT
ER FIRING
AND ASH
RE
MOV
AL
DOOR
ARE
C
LOSED.
SEE MA
NUAL
FOR
OPER
AT
ION OF WOO
D
FURNAC
E I
F E
LE
CTRI
CAL
POWE
R HAS BE
EN
IN
TER
RU
PT
ED.
THE HEA
T EXCHA
NGER
, FL
UE PI
PE AND
CH
IM
NE
Y M
US
T B
E I
NSPE
CT
ED FRE
QUE
NT
LY
AND
CL
EA
NED RE
GULARL
Y TO
R
EM
OVE
AC
CU
MU
LA
TED
CREO
SOT
E AND
AS
H.
UNDER
CER
TAIN
CO
NDITI
ON
S
OF USE
, C
REOS
OTE
BUILDU
P M
AY O
CC
UR RAP
IDL
Y.
EN
SU
RE
THA
T TH
E HEA
T E
XCHA
NG
ER,
FLUE
PI
PE AN
D CH
IMNEY
AR
E
CLEA
NED
AT
END
OF
BU
RNING
SEASON, T
HI
S HELPS
TO
M
INIM
IZE CO
RROSI
ON
IN
TH
E SUMM
ER MONTH
S. THE
APPLIANCE,
FLUE
PI
PE AND
CHIMNE
Y MUS
T BE
MA
INT
AINE
D
IN
GOOD
CONDIT
ION. U
NSAFE
TO
FI
RE
W
ITH W
OOD
ABOV
E T
OP
O
F R
EFRA
CTO
RY
BRICK
INSI
DE COMB
US
TIB
LE CHAMB
ER.
REPL
ACE
ALL
CRACK
ED
OR
BRO
KEN FIRE
BR
ICK
AND
TO
P B
AF
FLES.
LOAD
FUEL
CA
REFUL
LY
OR
DA
MAGE
MA
Y RES
UL
T.
DO
NOT
AT
TEMPT T
O
LIGHT
A FIRE IF
THERE I
S AN
OIL
VA
POUR PR
ES
ENT
.
DO NO
T
USE CH
EM
IC
AL
S O
R FL
UIDS
TO
ST
AR
T THE
FIR
E.
DO NOT
BURN
GARBAGE
, GAS
OL
IN
E, N
AP
HT
A, E
NGINE
OI
L O
R OTHE
R INAPP
ROPR
IATE MA
TER
IALS
.
DO
NOT
ST
ORE F
UEL
OR CO
MBUST
IB
LE M
ATE
RIAL
W
ITHIN
INS
TA
LLA
TIO
N CLEA
RANCES O
F TH
E APPLIANCE
.
DO NO
T
USE
TH
IS FURN
AC
E
WIT
HOUT
DU
CTS –
SEE MA
NUAL
FO
R ALL
OW
AB
LE
C
ONFIGU
RAT
ION.
CAU
TION
:
US
E SUP
PL
Y WIR
ES
SU
ITABLE F
OR 1
67°F/7
5°C. S
EE IN
STRUC
TION MA
NUAL
FOR
ELECT
RICA
L D
IAG
RA
M.
CAU
TION
: RE
PLACE G
LA
SS ONL
Y WITH C
ER
AM
IC
GL
ASS.
DANGER
: RI
SK
OF ELE
CT
RICAL
SHOCK.
DISCO
NN
ECT
P
OW
ER BE
FORE
SE
RV
ICING U
NI
T - DISC
ON
NEC
T P
OW
ER FROM B
OTH
FURNAC
ES
IN A
“A
DD ON
”
CONFIGURA
TION.
MAY
B
E AD
DE
D ON
TO
A
FURNACE
HA
VI
NG
A RA
TING A
S
SHO
WN
ON T
HE
ORIG
INAL
NAME
PLA
TE
BETWEE
N:
.:
0,1,0
80
$1
'
.
:0$
;,08
0)25(/
(&
75
,&)85
1$
&(
0,
1,08
0$1'0
$;,0
8086
*3
+)2
52,/
)851
$&(
0,
1,0
80
$1'0
$;,
080
%7
8+
)25
*$6)8
51$&
(
CAU
TION
: MAI
NT
AIN COM
BUS
TION
AI
R SUP
PL
Y TO
BOTH
FU
RN
AC
ES
. A
IR
STA
RVAT
ION
IS
D
AN
GER
OUS
(S
EE MA
NUAL
UN
DER
“OU
TSI
DE
CO
MBU
STI
ON A
IR
”).
FOR
“A
DD
ON”
INST
AL
LA
TIO
N
REFER
TO
MANU
FA
CTUR
ES INST
RUC
TIO
NS FR
OM
ORIGI
NAL
FU
RN
ACE F
OR INFOR
MA
TIO
N ON M
INIM
UM
DU
CT
SIZ
IN
G,
ALL
OW
ABLE
DU
CT
O
PENIN
GS I
N FU
RN
AC
E
CAS
ING
AND E
LE
CTR
IC DI
AGRA
MS A
ND
IN
FO
RM
ATION.
OPERA
TE ORI
GI
NAL
FU
RNACE
(EL
ECT
RI
C, OIL,
G
AS
) O
F A
“ADD ON”
C
ONFIGU
RA
TION
PE
RI
ODIC
AL
LY TO
ENS
URE
IT
WIL
L O
PE
RA
TE SA
TISF
ACT
OR
ILY
W
HE
N NEE
DE
D.
6 f
t
6”
1”
1.25”
MOD
EL
N
O.
SE
RIAL
NO.
MA
DE
IN CAN
AD
A W
ITH DOM
ESTIC
AND
IM
POR
TE
D P
AR
TS BY
:
W
OL
F S
TEE
L
LT
D.
24
NAPOLEON
R
OAD
, BA
RR
IE,
ON,
L4M
4Y
8 CA
NA
DA
18”
26”
26”
17”
14”
AN
D “S
”
1.25”
48”
“S”
14”
NO
TE:
“S”
=
MINIMU
M 24”
SE
RV
ICE
CLEAR
AN
CE
RE
QU
IRE
D
REFER
TO
SE
CTION
6.0
O
F THE
INS
TA
LL
AT
IO
N AN
D O
PE
RA
TING
IN
STR
UC
TIO
N MA
NU
AL.
W3
85-04
13
HM
F150
LISTE
D SO
LID F
UEL
F
IR
ED
CENT
RAL
F
UR
NA
CE
TEST
ED T
O:
CAN
-CSA
B
366-1
-M
91 /
UL391
4th E
d 2006
(JUL
Y 2008
) / UL
72
7 / C
SA B
14
0.4 /
CSA
B
212
MOD
EL
: H
MF150
REP
ORT
NO.
: _
415-
S-
09-2
_
CAUTION
:
HOT W
HILE IN
OPERA
TION.
DO
NOT
TO
UC
H.
KEE
P C
HILD
REN, CL
OTHING AND
FURNI
TURE A
WA
Y.
CO
NTA
CT MA
Y CAU
SE
SKIN B
URNS
. SEE NA
MEPLA
TE AND
INS
TR
UCTION
S.
TE
CHNICAL
DA
TA
BL
OWE
R /
VENTILA
TEU
R
1/
3 HP
ELE
CTR
ICAL
RA
TING
/
120V
, 10
.3 AM
PS,
ALI
MEN
TA
TIO
N EL
ECT
RIQUE
60
Hz
EX
TERN
AL S
TA
TIC PR
ESSU
RE
/
0
.2” W
.C.
PRE
SS
IO
N S
TA
TIQ
UE
EXT
.
0.
2” C
.E.
DR
AF
T P
RESS
URE/
WOOD
FL
UE:
MI
N. 0
.4”
W
.C
OIL FL
UE:
0.2
”W
.C.
OI
L F
UR
NA
CE
- O
IL F
IRING
RAT
E: 0
.66 GA
L US
- O
IL
PRESS
UR
E:
120 PS
I
- N
OZ
ZLE:
0.
65
- 60
°A
INST
ALLA
TION
- USE
O
NLY
IN
ACCO
RDANCE WI
TH W
OLF
ST
EE
L L
TD’S INS
TRUC
TIONS
. CO
NT
ACT
LOC
AL
BU
ILDING,
FI
RE
OFF
IC
IAL
S AND
OT
HER AGE
NC
IES
HA
VIN
G
LOC
A
JU
RISDICTI
ON ABO
UT
RE
STR
IC
TIONS A
ND INST
ALLA
TION
IN
SPECTION
IN
YOUR
AR
EA.
CHIMNE
Y TYPE
: FO
R “
WO
OD O
NL
Y” FURNA
CE
CONF
IGURA
TION
MIN
IM
UM
6”
(15
2mm
) DIAME
TER
LIST
ED
(UL
103
HT)
RE
SIDE
NT
IA
L CH
IM
NEY
. F
OR “W
OOD/
OIL
COMBIN
ATION” F
URNA
CE
RECOM
MENDE
D M
INIM
UM
7”(178mm
) DI
AMETE
R
LIST
ED
(U
L 103HT
) RE
SI
DENTIAL
CHIM
NEY
.
DO
NO
T CONN
ECT
THI
S U
NI
T TO
A
C
HI
MNEY
FLUE
SER
VI
NG
ANO
TH
ER AP
PLIA
NC
E
UNLE
SS
U
SING
IN
A “
AD
D
ON” C
ONFIG
URA
TIO
N
W
ITH
A
PR
E
EX
ISITNG
OIL
FURN
ACE -
SE
E MAN
UA
L U
ND
ER PLENUM
AN
D I
NS
TALLA
TIO
N.
CHIMNEY
CONNECT
OR
: 6
” (1
52
mm) D
IAME
TER
MINIMUM
24 GAUGE S
TEE
L M
INIMU
M C
LEA
RA
NCE
FROM
HO
RIZONT
AL
CON
NE
CT
OR
AN
D
CE
ILI
NG 1
8” (455
mm).
SP
ECI
AL
METH
ODS AR
E
REQU
IRED
WHEN P
ASS
ING A
C
HIMN
EY
THROU
GH A
W
AL
L OR CE
ILI
NG
. SE
E I
NS
TRUCTI
ONS
AND
BU
ILDING
CODES.
DO NOT OBSTRUCT
SP
ACE U
NDE
R FUR
NACE
.
UNIT
C
AN BE
INST
ALLE
D ON
COMBUST
IB
LE
S
URF
ACE
(W
OOD
SUBSTRA
TE O
NL
Y –
CARPET
AN
D
OTHE
R FLOOR
COV
ERI
NG
S T
O BE
R
EM
OVE
D)
PROVI
DING E
MBE
R
ST
OP S
HI
ELD (SEE
MANUA
L) INS
TALL
ED
BE
TW
EE
N
FURNACE
AND
FLOO
R
AN
D M
IN
IMUM
1
¼” AIR
GAP
MAINT
AI
NED B
ETW
EEN
FU
RN
AC
E A
ND
FLOO
R.
FUEL
: FOR
US
E WITH
SO
LID
W
OO
D FUE
L ONL
Y. DO
NO
T U
SE
G
RA
TE
O
R ELE
VAT
E F
IR
E. BU
ILD W
OOD FI
RE
DIR
ECTL
Y O
N H
EAR
TH.
AUTHORIZE
D MO
DULES
FOR
C
ONNE
CTION
TO
HMF150
FU
RNACE
:
BLOW
ER BO
X MODU
LE
-
HM
FK-B
MP
33
EL
EC
TRIC
FURNA
CE MO
DU
LE -
HMF
K-E
F2
0
OIL
FU
RNACE
MO
DU
LES -
HMF
K-OFRF40
,
HM
FK-
OFA
FG
DHW PRE
HEA
T M
ODU
LE
-
HMFK-
DH
W
“ADD ON
” FU
RNACE MO
DULE
-
H
MFK-AD
DON
TH
ESE
AR
E T
HE O
NL
Y AUT
HORIZED
COM
PO
NENTS
THA
T MA
Y BE
ATT
AC
HE
D TO
TH
E HMF1
50
FUR
NA
CE
ASIDE FR
OM CONNE
CT
ION
TO
FO
RC
ED A
IR SY
STE
M
RETURN
AN
D S
UPP
LY
PLE
NUMS.
MO
DULES
MU
ST
BE
INS
TA
LLE
D T
O
MANU
FAC
TURERS I
NSTRU
CTI
ON
S
POSTE
D IN
TH
E
INS
TA
LL
AT
ION/O
W
NE
RS M
ANUAL
ACCOMP
ANYING
HMF150
AND
INSTRUC
TION
AD
DENDU
MS INCL
UD
ED W
ITH
EACH MO
DULE
.
THE H
MF150 FU
RNAC
E IS
CER
TIFI
ED
FOR SER
IES C
ON
NECTION
TO
TH
E SUP
PL
Y PL
EN
UM
OUT
LET
ONL
Y OF A
G
AS F
IRED
, O
IL
FIR
ED,
OR
E
LECT
RIC
FURN
ACE
W
HEN
USED A
S AN
W
OOD
FUR
NACE “A
DD-
ON”
.
DO NOT C
ONNECT
TH
IS
FUR
NACE T
O
A CHI
MNE
Y SER
VIC
E A
GAS F
URNA
CE.
DO NO
T CO
NNECT DU
CTWO
RK SO
THA
T RE
VERSE
FLOW IS POS
SI
BL
E.
DO
NOT R
EL
OCA
TE
O
R BYP
ASS
AN
Y OF THE S
AF
ET
Y CONTR
OLS IN
TH
E
OR
IGINAL
FU
RNAC
E
INS
TA
LLA
TION (”ADD O
N”
CON
FIG
URA
TION
).
CA
UT
ION
: TH
IS
AP
PL
IANC
E M
UST
BE
INST
ALL
ED
B
Y A Q
UA
LIF
IED
IN
ST
ALLE
R.
US
E
OF UN
AUT
HO
RI
ZE
D
CO
MPO
NENT
S O
R FA
ILURE
TO
COMP
LY
WITH
INS
TA
LL
AT
ION INS
TRU
CTIONS WI
LL
R
ES
UL
T IN
V
OI
DED W
ARRA
NTY
.
WARNIN
G
: RI
SK OF S
MO
KE
S
PI
LLAGE
. OPE
RAT
E O
NL
Y WIT
H FI
RI
NG
AN
D ASH
REMO
VA
L DO
OR TIG
HTL
Y CL
OSED. DO
N
OT
OVE
RFIRE.
IF HEA
TER OR C
HIMN
EY
CONN
ECT
ORS G
LOW
, YO
U
ARE O
VE
RF
IRIN
G
– IMMED
IATEL
Y TU
RN O
FF THERMO
STAT
A
ND EN
SURE P
RIMAR
Y SHUT
TER FIRING
AND
ASH
RE
MO
VA
L D
OO
R
ARE C
LOS
ED.
SEE
MA
NU
AL
FOR OPER
AT
ION
OF WOO
D
FU
RNAC
E I
F ELE
CTRI
CAL
POW
ER
H
AS
BE
EN
IN
TER
RUPT
ED
.
THE HEA
T E
XC
HA
NGER
, FLUE P
IPE AND
CH
IM
NE
Y MUST
BE
INSPE
CT
ED
FRE
QUE
NTL
Y AND
CL
EAN
ED R
EGULARL
Y T
O R
EM
OV
E AC
CUMULA
TED
CR
EO
SOTE AND
AS
H. UNDER
CER
TA
IN
C
OND
ITIO
NS
OF
USE
, C
REOS
OTE
BUILDU
P MA
Y O
CC
UR
RAP
ID
LY
. E
NSUR
E THA
T TH
E HEA
T E
XCHAN
GER,
FLUE
PI
PE AN
D CH
IMNEY
ARE
CLEA
NED A
T END
OF
BURNING
SEA
SON
, T
HI
S
HEL
PS
TO
M
INIMIZE CO
RROSI
ON IN
TH
E S
UMME
R MONTH
S. THE
APPL
IANCE, FLUE PI
PE A
ND
C
HIMNE
Y M
US
T BE
MAINT
AINE
D IN GOO
D
CONDIT
IO
N. U
NSAFE
TO
FIRE WI
TH
W
OOD
ABOV
E T
OP
O
F R
EF
RA
CTO
RY
BRICK
INSI
DE
COMB
US
TIB
LE CHAMB
ER.
REPL
ACE
ALL
CR
ACK
ED
OR
BR
OK
EN FIRE
BR
ICK
AND
TO
P BAF
FLES.
LOAD
FUEL
CAREFUL
LY
OR DA
MAGE
MA
Y
RES
UL
T.
DO
NOT
AT
TEMPT T
O
LIGHT
A
FIRE
IF
THERE IS
AN O
IL V
AP
OUR PR
ES
ENT
.
DO
NO
T
USE CH
EMIC
ALS OR
FLUIDS
TO
S
TAR
T THE
FIR
E.
DO NO
T
BUR
N GARBAGE
, GA
SO
LINE
, N
APH
TA, E
NGINE O
IL O
R O
THE
R
INAPP
ROPR
IAT
E MA
TERIALS
.
DO NO
T
ST
OR
E F
UEL
OR
CO
MBUSTIB
LE M
ATE
RIAL
W
ITHIN INS
TA
LL
AT
IO
N CLEA
RANCE
S O
F TH
E APPLIANCE
.
DO NO
T
USE
TH
IS FURN
ACE
WIT
HOUT
DU
CTS
– S
EE
MA
NUAL
FO
R AL
LOW
AB
LE
CONFIGU
RAT
ION
.
CAU
TION:
US
E SUP
PL
Y W
IRE
S SU
ITABL
E F
OR 1
67°F/7
5°C. S
EE IN
STRUC
TION
MA
NU
AL
FOR
ELECT
RICA
L DIAGR
AM
.
CAU
TION
: RE
PL
AC
E
GL
ASS ONL
Y WITH C
ERAM
IC
GL
ASS.
DANGER
: RISK O
F E
LE
CTR
ICAL
SHOCK.
DISCO
NN
ECT
P
OWER BE
FO
RE
S
ER
VICING UNI
T -
DISC
ONNEC
T POWE
R
FROM B
OTH
FURNA
CES
IN
A “A
DD ON
”
CONFI
GURA
TION.
MA
Y BE
AD
DED
ONT
O
A F
URNACE
HA
VING
A R
AT
ING AS
SHO
WN
ON T
HE
ORI
GI
NAL
NAME
PLA
TE
BETWEE
N:
.:
0,
1,0
80
$1'
.
:0$;
,08
0)25(/
(&75,&
)85
1$
&(
0,1,08
0$1'
0
$;,0
80
86
*3+
)2
52,/
)851
$&(
0,
1,08
0$1'
0
$;
,080%7
8+
)25
*$6)8
51$&
(
CAU
TIO
N
: M
AI
NT
AIN COM
BUST
ION A
IR SUPPL
Y T
O
BOTH
FURN
ACES
. A
IR
STA
RVAT
ION
IS
DA
NGEROU
S (
SEE MA
NUA
L UN
DER
“OU
TSIDE
COMBU
STION A
IR
”).
FOR
“ADD
O
N”
INST
ALLA
TION
REFER
TO
MANU
FA
CT
UR
ES INST
RUC
TIO
NS
FRO
M OR
IG
INAL
FU
RN
ACE F
OR
INF
OR
MA
TIO
N ON M
INIM
UM
DU
CT
SIZ
IN
G,
ALLOW
AB
LE
DUCT
O
PENIN
GS IN FU
RN
ACE
CAS
ING
AND
EL
ECTR
IC
DI
AGRA
MS A
ND IN
FORM
ATIO
N.
OPERA
TE OR
IGINAL
FU
RNAC
E
(ELECT
RIC, OIL,
G
AS) O
F A
“ADD ON”
C
ONFIG
URA
TION
PERI
ODIC
AL
LY
TO
ENS
URE
IT
WIL
L OPE
RA
TE SA
TISF
ACT
OR
ILY
WH
EN NEED
ED.
6 ft
6”
1”
1.25”
MODEL
N
O.
SE
RIA
L NO.
MADE
IN CAN
AD
A W
ITH DOM
ESTIC
A
ND
IM
PO
RT
ED
PA
RT
S
BY:
WOLF
STEE
L
LT
D.
24
NAP
OLE
ON
R
OAD
, BARR
IE, ON,
L4M
4Y
8 C
ANA
DA
18”
26”
26”
17
”
14”
AN
D “S
”
1.25”
48”
“S”
14”
NO
TE:
“S”
=
MINI
MU
M 24”
SE
RV
ICE
CL
EARAN
CE
RE
QU
IRE
D
RE
FE
R TO
SE
CTI
ON
6.0
O
F THE
INS
TA
LLA
TION
AN
D
OP
ER
ATING
IN
STR
UC
TION
MA
NU
AL.
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...