W415-0910 / A / 09.16.10
10
W3
85
-041
3E
/ 0
7.1
4.1
0
LIST
ED S
OLID
F
UEL
FI
RED CENTR
AL
FURNACE
TESTED T
O:
CA
N-CS
A B366
-1-
M9
1 /
UL39
1 4
th Ed 2006 (JUL
Y 20
08) / U
L 727 / C
SA
B140.4 / CSA
B212
MODEL: HMF150
RE
POR
T NO
.: _
415-
S-09
-2
CAUTION
:
HOT WHILE IN OPERA
TION. DO NOT T
OUCH. KE
EP
CHILDREN, CLOTHING
AND
FURNITURE A
WA
Y.
CONT
ACT M
AY
CA
US
E S
KIN BURNS.
SE
E NAM
EPLA
TE A
ND
INSTRUC
TIO
NS.
TE
CHNICAL DA
TA
BL
OWER
MO
TO
R
1/3 HP
EL
EC
TRI
CAL R
AT
IN
G
120V
, 11 A
MP
S,
60H
z
ELECTR
IC
FU
RN
ACE MOD
ULE
220V
, 84
AM
PS
EX
TE
RN
AL
ST
ATIC P
RESS
URE
0.2”
W
.C.,
0.2”
C.E.
DR
AF
T P
RESSUR
E
WO
OD
FL
UE:
MIN
. 0.04“
W.
C. T
O M
AX.
0.
06”
W
.C.
OIL
FL
UE:
M
IN
. 0
.02”
W
.C.
TO
MAX.
0.04”
W.
C.
OIL
FU
RN
AC
E MAX
. FIRIN
G
RAT
E 91,
000
BT
U
INP
UT
AS S
HI
PP
ED:
- OI
L PR
ESS
UR
E:
120
PSI
- NO
ZZ
LE:
0
.65 -
60
°A
- NO
. 2
FUR
NA
CE
OIL
INST
ALLA
TION USE
ON
LY I
N ACCO
RD
ANCE W
ITH
WOLF STE
EL L
TD’
S INS
TRU
CTIONS
. C
ONT
AC
T L
OC
AL
BUILDING
OR FIRE OF
FICI
ALS
OR O
THER
AUTHORI
TIES HA
VIN
G
JU
RISDICTION
ABO
UT
RE
STRICTI
ON
S A
ND
INST
ALLA
TION
INSP
ECT
ION
IN YOUR
AR
EA.
CAUT
ION
: THIS
A
PPLIAN
CE
MUST
B
E IN
ST
AL
LED B
Y A
Q
UALIF
IED
INS
TA
LLER.
USE OF
UNA
UTHO
RIZED COM
PONE
NTS
OR F
AILU
RE T
O C
OM
PLY
WITH INST
ALLA
-
TION
INSTRUCTION
S WIL
L RESUL
T IN VOI
DED
WA
RR
AN
TY.
CH
IMN
EY T
YPE
: FO
R “W
OOD
ONL
Y” F
URNA
CE
CO
NF
IGU
RA
TION M
INIMUM 6” (15
2mm)
DIA
METER
LIS
TED (UL
103HT
) RES
IDENT
IAL
CHI
MN
EY
. F
OR
“W
OOD/OIL
COMBINA
TIO
N” FU
RNACE
RE
COMMENDE
D MINIMUM
7”(178mm) DI
AMETE
R LISTED (
UL
103
HT
) R
ES
IDENTIA
L C
HIMN
EY
.
CHIM
NEY
C
ONNEC
TO
R
: 6”
(152
mm
) DI
AMETER
MINI
MUM 2
4 G
AUGE
STEE
L M
INI
MUM
CLEAR
AN
CE
FRO
M HO
RIZONT
AL
CONNEC
TOR
AND
CE
ILIN
G 18” (455mm)
.
SP
ECIA
L M
ETHO
DS ARE
REQ
UIR
ED
WHE
N PA
SSING
A CHIMNE
Y THRO
UGH A
WA
LL
OR C
EIL
ING
. SEE
INST
RUCT
IONS
AND
BUILDING
CODES
.
DO NOT
C
ON
NE
CT
THIS UN
IT T
O
A C
HIMN
EY
FLU
E S
ER
VIN
G A
NO
THER APPLI
ANCE. E
XC
EP
TIO
N “A
DD ON
” CON
FIGU
RAT
IO
N WIT
H AN
OIL
FURNA
CE
R
EF
ER
TO MANUAL
.
DO
NO
T CONNECT
TH
IS
FURNA
CE T
O
A CHIMNEY
SER
VICE A
G
AS
AP
PLI
ANCE
.
FUEL
: FOR
USE
WI
TH S
OL
ID W
OO
D F
UE
L ON
LY. D
O NOT
US
E GRA
TE
OR ELE
VATE
FIRE.
BU
ILD
W
OOD
FIR
E D
IRECTL
Y O
N HEA
RT
H.
LOA
D F
UEL
CA
REFU
LLY
OR D
AM
AGE
MA
Y
RESUL
T.
OIL
FU
RNA
CE MODULE
NO.2 FU
RN
ACE
OIL
DA
NGE
R:
RISK
OF
FIR
E O
R EXPLO
SIO
N.
DO
NOT
AT
TE
MP
T T
O L
IGHT
A
FIRE
IF THERE IS
AN
O
IL V
AP
OUR
PRESEN
T.
DO NO
T
USE
CHEMICALS
OR FL
UIDS T
O S
TA
RT T
HE
FIRE.
DO NOT
BURN
GARBAGE
, GASO
LINE
, NAPHT
A, ENGI
NE
OIL
OR OTHE
R IN
AP
PR
OP
RIA
TE
MA
TE
RIALS
.
DO
NOT
ST
OR
E FUEL
OR CO
MBU
ST
IBLE MA
TER
IAL
WITHI
N IN
STA
LLA
TION CL
EAR
ANCES OF
TH
E AP
PLI
ANCE.
DO
N
OT
USE T
HIS
FURNACE W
ITHOUT
DUCTS – SEE
MANUAL
FOR
AL
LOW
ABL
E C
ON
FIGU
RA
TION.
WA
RN
IN
G
:
RISK O
F SM
OKE
SPI
LLA
GE. O
PERA
TE
ONL
Y W
ITH FIRIN
G A
ND
AS
HP
IT D
OO
R TIGHTL
Y CLO
SED.
DO
NOT
OV
ERF
IRE
.
IF
HEA
TER
OR CHI
MNEY
CONN
EC
TO
RS
GLO
W,
YOU
AR
E O
VERF
IR
ING – IMM
EDIA
TEL
Y TURN
OFF
TH
ERMO
ST
AT AN
D
ENSUR
E PRIM
AR
Y SHUTTER
FI
RING
AN
D A
SH
PIT D
OO
R A
RE C
LOSED.
CAU
TION
: MAINT
AIN
COM
BUSTION A
IR SU
PPL
Y T
O BOT
H FU
RNACES.
AI
R ST
AR
VA
TION IS DANG
EROU
S (SEE
MANU
AL
UND
ER “OUT
SID
E C
OMBUSTIO
N AIR
”.
THE HMF
150 F
UR
NAC
E MA
Y B
E CONNE
CT
ED
TO D
UCT
WORK (S
UPPL
Y SID
E –
SEE
MANUAL
) OF ANOT
HER FURNACE
WHEN
US
ED
AS AN
WOOD
FUR
NAC
E “
ADD-ON
”.
CE
RT
IFIE
D FOR
SERIES CON
NECTION T
O THE
SUPPL
Y PLE
NU
M O
UT
LET
ONL
Y OF
A GAS FI
RED, O
IL FIRED, O
R ELECTR
IC FURNACE.
DO
NOT
CO
NNE
CT
DUC
TW
OR
K SO TH
AT RE
VERSE
FL
OW IS
PO
SSIBLE.
FOR
“ADD ON”
INS
TA
LLA
TIO
N R
EF
ER
TO
MA
NU
FA
CT
URES I
NS
TRUCTION
S F
ROM
ORIGINA
L F
URNAC
E FOR IN
FO
RMAI
TON
ON MINI
MUM D
UCT
SIZI
NG,
ALLOW
ABLE
DU
CT
OP
ENING
S IN FURNA
CE CASING
AN
D ELECTR
IC DIAGRAM
S AND
IN
FORMA
TIO
N.
DO N
OT RE
LO
CA
TE
OR BYP
ASS
ANY
O
F T
HE
SAF
ETY
CONTRO
LS IN T
HE
ORIGI
NAL
FURNACE
IN
ST
ALLA
TION (“AD
D ON”
C
ONFIGUR
AT
ION).
DO
NO
T OBS
TRUCT
SPA
CE
UNDER F
UR
NACE.
UNIT
CAN
BE
INST
ALLE
D ON CO
MB
UST
IBL
E SURF
AC
E (W
OOD SU
BST
RA
TE ONL
Y – CA
RP
ET A
ND O
THER
FLOO
R
CO
VER
INGS T
O BE
REMOVED) P
ROV
IDING
EMBER ST
OP S
HIELD
(S
EE MANU
AL)
IN
STA
LLED
BET
WEEN
FUR
NAC
E AND
FLO
OR AND
MINIM
UM 1
1/4
” AIR
GA
P
MA
INT
AIN
ED BETWEE
N FU
RNACE
AN
D FLO
OR
.
INCASE OF P
OW
ER
FA
ILU
RE:
PUS
H DO
WN
ON
THE C
ONT
ROL
ARM
OF
THE
PRIMA
RY A
IR
CO
NT
ROL
AN
D LOCK I
T DOWN
USI
NG
ROT
ATI
NG
CLASP
. TO
AVO
ID
EXC
ESS
IVE
HE
AT B
EING TRAPP
ED
IN DU
CT
WORK
EN
SURE
ALL
RETUR
N AND
SU
PPL
Y AIR R
EGIS
TER
S ARE
NO
T B
LO
CKED B
Y O
BJECT
S OR
DEB
RIS
AN
D ALL
DU
CT
CO
NTR
OL D
AMPERS AR
E S
ET
OP
EN.
SEE M
ANU
AL F
OR
OP
ERA
TIO
N OF
W
OO
D F
URN
AC
E IF E
LEC
TRICAL
POWER
HAS BEE
N INTERRUPTE
D.
OPER
AT
E O
RIG
INAL
FURNA
CE
(EL
ECTRI
C, OI
L, G
AS)
OF
A “ADD ON” C
ONFIGUR
AT
ION PERI
OD
ICALL
Y T
O ENSUR
E IT
WILL
OPERA
TE
SA
TISF
AC
TORI
LY W
HEN
NEEDE
D.
THE
HEA
T EX
CHA
NGER,
FLU
E PIPE
AN
D C
HIM
NE
Y M
US
T BE I
NSPE
CTE
D F
REQUENTL
Y AN
D CLEA
NED
REGULA
RL
Y T
O REM
OVE ACCUM
UL
AT
ED
CR
EOS
OTE
AND
ASH. UNDE
R CER
TA
IN
CONDITIO
NS O
F USE, C
REOS
OTE BUI
LDUP
MA
Y OC
CUR
RAPIDL
Y. EN
SURE THA
T THE
HE
AT
EX
CHANG
ER
, F
LUE P
IPE
AND
CHIMN
EY
AR
E
CLE
AN
ED
AT E
ND OF
BURN
ING SEA
SO
N,
THIS HE
LPS T
O MINI
MIZ
E CORRO
SION IN
THE
SU
MMER
MONTHS.
THE
APP
LIA
NCE, F
LUE
PIPE
AND
CH
IMN
EY
MUST
BE
MAI
NT
AINED
IN GO
OD
CONDITION. U
NSAFE
TO
FIRE W
ITH WOOD
AB
OVE
TO
P OF R
EFRACT
OR
Y BRICK
INSI
DE COMBU
ST
IBLE
CH
AM
BER
.
USE
SUPPL
Y W
IRES SUI
TAB
LE FOR 1
67°F/75°C.
SE
E INS
TR
UC
TION
MANU
AL
FOR
ELEC
TRI
CAL
DIA
GRAM.
DANGER
: R
ISK O
F ELECTRI
CAL
SH
OCK
. D
ISCONNEC
T P
OWE
R B
EFORE
SER
VIC
ING
UNIT
. FO
R M
OR
E INFORM
AT
ION R
EF
ER T
O OWNER’S M
ANUAL.
CA
UTION
: TWO
SOURC
ES OF E
LECTRIC
AL
ENERGY
PRE
SENT
IN
ELECTRIC
FURN
ACE MO
DULE
- DIS
CONNE
CT
220V S
UPPL
Y T
O MODULE
AND 120V
SU
PP
LY
TO
HMF
150
FURNACE BE
FO
RE
SE
RV
ICING
.
REP
LACE ALL
CR
ACKE
D OR
BROK
EN F
IRE
BRICK
AN
D T
OP
BAFF
LES. REPLA
CE GLA
SS O
NL
Y WITH C
ERAMI
C GLASS
.
AUT
HOR
IZED MO
DUL
ES FOR
CONNE
CTION T
O HMF150
FURNACE
: BLOWE
R B
OX M
ODU
LE
-
HMFK
-B
MP33
, EL
ECT
RIC
FURN
ACE MO
DULE-
HMFK
-EF20,
OIL F
URNAC
E
MO
DU
LES
-
HMFK-O
FR
F40
,
HMFK
-OF
AF
G,
DHW
PREHEA
T MODULE
-
HMF
K-
DH
W,
“AD
D ON” KIT
-
HM
FK-A
DD
ON
TH
ESE
ARE
THE ONL
Y AU
TH
ORIZED COM
PONENT
S TH
AT
MA
Y B
E AT
TA
CH
ED
TO
THE
HMF
150 F
URNACE ASI
DE FROM
CONN
ECTI
ON
TO FOR
CED A
IR
SY
STEM
RE
TURN
AND
SUPPL
Y P
LE
NUMS
. MODULE
S MUST
BE
INST
ALLE
D T
O M
AN
UF
ACT
URE
RS IN
ST
RU
CT
ION
S PO
ST
ED IN
THE INST
AL
LATIO
N/O
WN
ER
S MANUAL
ACC
OMP
A-
NYING HM
F1
50 A
ND
INS
TRUC
TION
AD
DEND
UM
S INCLUDED
WITH EA
CH
MODUL
E.
HMF150 C
ONFIGUR
ED
AS A
N “
AD
D O
N”:
MAY
BE
AD
DED ON
TO
A FURN
AC
E H
AV
ING
A R
AT
ING
AS SHOW
N ON
THE
ORIG
INA
L N
AM
E P
LATE B
ETW
EE
N:
15
KW
MINIMUM
AN
D 2
0 KW M
AXIMUM
FOR EL
ECTR
IC FU
RNAC
E
0.4 M
INI
MUM A
ND 0.71
MA
XIMUM
USGPH
FO
R OIL
FURN
ACE I
NPU
T
80,00
0 MAX
IMU
M BT
U/H
FOR G
AS
FU
RNACE INP
UT
REFER T
O
OWNERS MA
NUA
L
WOLF
STEEL
LT
D.
24
NAP
OLEON RO
AD
, BARRI
E, ON,
L4M 4Y
8 CANA
DA
18”
MA
X 1
6”
CL
EA
RA
N
CE
T
O
C
O
M
BU
SI
BL
ES
SE
RV
IC
E
CL
EA
RA
N
CE
24”
14”
CL
EA
RA
N
CE
T
O
C
O
M
BU
SI
BL
ES
SE
RV
IC
E
CL
EA
RA
N
CE
24”
LEFT
HA
ND R
A C
ONF
IGU
RAT
ION
(RE
AR
VIE
W)
M
IN
IM
U
M
4
0”
18”
14”
M
IN
IM
U
M
5
2”
9”
*Dr
awi
ng
not
to
scale
O
IL
F
U
R
N
A
C
E
F
L
U
E
WOOD
, WO
OD
/OIL
FLUE
NO
TE
:
RE
FE
R T
O MA
NU
AL
FO
R R
IGH
T H
AN
D C
ONF
IGUR
ATION
CL
EAR
ANC
E TO
COMB
US
TIBL
ES.
THE EL
EC
TRIC FURN
AC
E M
OD
ULE
(NOT
SH
OW
N) F
ALLS
WITH
IN
ENVE
LOP
E O
F CL
EARANC
E T
O C
OMBUS
TIBLES
FO
R WOOD
, W
OOD/
OIL
CO
NF
IGU
RA
TION
- THE
CLEARAN
CE
ENVE
LOPES DO NOT
CH
AN
GE WITH
AD
DITION OF
TH
E ELE
CT
RIC
FU
RNACE.
CL
EA
RA
N
CE
T
O
C
O
M
BU
ST
IB
LE
S
CLEA
RANC
E TO
CO
MB
UST
IBL
ES
48”
18”
24”
1.2
5”
CL
EA
RA
N
CE
T
O
C
O
M
BU
ST
IB
LE
S
SE
RV
IC
E
CL
EA
RA
N
CE
LEFT
HA
ND R
A C
ON
FIG
URA
TIO
N (SID
E VIE
W BL
OWER MOD
ULE)
9”
*Dr
aw
ing
no
t to
sca
le
O
IL
F
U
RN
AC
E F
LU
E
WO
OD,
WO
OD/OIL
FLU
E
NOT
E:
SEC
TIO
N “
C” C
LEA
RA
NC
ES M
AY
BE REDUCE
D TO
0.37
5”
BEY
OND A
BEND
OR
OFFSE
T IN
TH
E DUC
T SU
FFI
CIEN
TLY LARGE
TO
SH
IELD
THE
RE
MAIN
DE
R O
F
THE
SU
PPL
Y D
UC
T FROM DIREC
T R
AD
IAT
ION FROM
THE
FU
RNA
CE H
EA
T
EX
CH
ANG
ER.
72”
1”
6”
7
f
t.
M
IN
IM
U
M
C
E
IL
IN
G
H
E
IG
H
T
CLE
AR
AN
CE
TO
CO
MBUS
TIB
LE
S
40”
>72”
A
B
C
NO
TE:
Se
e
CA
N/C
SA
-
B3
65.0
1 an
d
NFP
A21
1 f
or
cle
aran
ce
to
co
mbusti
ble
specific
ation
s
for r
eturn
air
duc
ting
.
*Dr
aw
ing n
ot t
o sc
ale
CLEA
RANCE
TO
COMBUSTIBLES
SE
CTI
ON
A
B
C
TOP
6”
6”
1”
BO
TT
OM/S
IDES
18”
6”
1”
SERI
AL
NO.
HMF150
MA
NUF
ACT
URE D
AT
E:
JAN
AP
R
JUL
OCT
FEB
MA
Y
AUG
NOV
MA
R
JUN S
EP
DEC
2010
201
1 2012 20
13
W3
85-
041
3E
/ 0
7.14
.10
LISTED SOL
ID FUEL
FIRED CENTR
AL
FURNACE
TESTED T
O:
CAN-CSA
B366-1
-M91 / UL391 4t
h Ed
20
06 (JUL
Y 20
08) / UL
727 / CS
A B140.4 /
CSA
B212
MO
DEL: HMF150
RE
PO
RT
N
O.
: _
415-S
-09
-2
CAUTION
:
HOT WHILE IN OPERA
TIO
N. DO
NOT T
OUCH. KE
EP
CHILDR
EN, CLOTHI
NG AND
FURNITURE A
WA
Y.
CONT
ACT
MA
Y CAUSE SKI
N BURNS. SE
E NAM
EPLA
TE A
ND
INSTRUCTION
S.
TECHNICAL DA
TA
BL
OW
ER
MO
TO
R
1/3 HP
EL
ECTRI
CA
L R
AT
IN
G
12
0V
, 11
AM
PS,
60H
z
ELEC
TR
IC
FUR
NA
CE
M
OD
UL
E
220V
, 84 AM
PS
EX
TE
RN
AL ST
ATIC P
RESSURE
0.
2” W
.C.,
0.2”
C.E.
DRA
FT PRE
SS
UR
E
W
OOD F
LU
E: MIN
. 0
.04“
W
.C.
TO
MA
X.
0.06”
W
.C.
OIL
FL
UE:
M
IN.
0.02”
W
.C.
TO MAX.
0.04”
W.
C.
OIL
FU
RN
ACE MAX
. F
IRI
NG R
AT
E 91
,00
0 B
TU
INP
UT
AS
SHIPP
ED:
- OIL
PR
ES
SUR
E:
120
PS
I
- NO
ZZ
LE:
0.6
5 -
60°
A
- N
O. 2
FUR
NA
CE OIL
INS
TALLA
TIO
N USE
ONL
Y IN
AC
CO
RDA
NCE W
ITH
WOLF STEE
L L
TD’S
INS
TRUCTIONS.
CONT
AC
T L
OCAL
BUILDI
NG
OR
FIRE
OF
FIC
IAL
S OR O
THER
AUTHORI
TIES HA
VING
JU
RIS
DIC
TIO
N A
BOUT
RE
STRICT
ION
S AND INST
AL
LAT
ION
IN
SPE
CTION
IN
YOUR A
REA.
CAUT
ION
: T
HIS
APPLIAN
CE MUST
BE IN
ST
ALL
ED
BY
A
QUALIFIED I
NS
TA
LLER.
USE OF
UNAUTH
OR
IZED COM
PONE
NT
S OR F
AILU
RE
TO C
OM
PLY
WITH INST
ALLA
-
TIO
N I
NSTRUCTIONS
WI
LL
RESUL
T IN VOIDED W
AR
RANTY
.
CHIMN
EY T
YPE
: FOR “W
OOD
ONL
Y” F
URNAC
E C
ONF
IGURA
TION
MI
NIM
UM
6”
(152mm) DIA
METER LIST
ED (U
L 103HT
) RESID
ENT
IAL
CHI
MNEY
. F
OR
“WO
OD
/OIL
COM
BINA
TIO
N”
FU
RNACE
RE
COMMENDE
D MINIM
UM
7”(178mm) DI
AMET
ER LI
STED
(U
L 1
03HT
) RES
IDEN
TIA
L CHIMNEY
.
CHI
MNEY
CONNEC
TO
R
: 6” (152m
m) DI
AMETER MINI
MUM 24 G
AUG
E STEEL
MINI
MUM
CLE
AR
AN
CE FR
OM HO
RIZ
ON
TA
L CONNECT
OR AND
CEI
LIN
G 18” (455mm)
.
SPEC
IAL
METHODS
ARE
RE
QU
IRE
D WHE
N P
AS
SING
A CHIMNEY
TH
RO
UG
H A
WALL
OR
CE
ILING
. SEE
INSTRUCT
IONS
AN
D BUILDING
CO
DES.
DO NO
T CON
NECT
THI
S UNIT
TO
A C
HI
MN
EY
FLUE
SE
RV
IN
G
AN
OTH
ER A
PPL
IANCE. E
XC
EPTI
ON “
AD
D ON” CON
FIGUR
AT
ION WITH
AN OI
L FU
RNA
CE
REF
ER
TO
MANUAL
.
DO
N
OT CON
NE
CT
TH
IS FURN
AC
E T
O
A CHI
MN
EY
SER
VIC
E A
GA
S APPLI
AN
CE
.
FU
EL
: FOR USE
WIT
H SO
LID W
OO
D FUEL
ONL
Y. D
O NOT
US
E G
RA
TE
OR
EL
EVAT
E FIR
E.
BU
ILD
WOOD
FIRE
DIRE
CTL
Y ON HEA
RT
H.
LOAD
FUEL
CAREFU
LLY
OR
DAMAGE
MA
Y
RESUL
T.
OIL
FU
RNA
CE
MO
DUL
E N
O.2 FU
RN
AC
E O
IL
DA
NG
ER:
RI
SK
OF
FIR
E O
R EXPLOSI
ON.
DO
NO
T AT
TE
MP
T TO
LIGHT
A F
IRE
IF THE
RE IS
AN OIL
VAP
OUR PRES
EN
T.
DO
NOT
USE
CHEMICALS
OR
FLUIDS
TO
ST
AR
T THE
FIRE.
DO
NOT
BURN
GARBAGE
, GASO
LINE
, NAPHT
A, ENGI
NE OIL
OR OTHE
R INAP
PR
OP
RIA
TE
MA
TERI
AL
S.
DO
NOT
ST
OR
E FUE
L OR CO
MBUS
TIBLE
MA
TER
IAL
WITH
IN IN
STA
LLAT
ION C
LEAR
ANCES O
F T
HE A
PPL
IANCE
.
DO
NOT
USE
THIS
FUR
NACE W
ITH
OUT
DU
CTS –
SEE
MANUAL
FOR
ALLOW
ABLE
CO
NFIGU
RA
TIO
N.
WARN
ING
:
RIS
K O
F SMO
KE
SPILLAGE.
OP
ERA
TE
ONL
Y W
ITH
FIRING
AND AS
HP
IT DOO
R TIG
HTL
Y CLO
SED. DO
NO
T O
VE
RF
IRE.
IF HE
ATE
R O
R C
HI
MN
EY
C
ONN
ECT
OR
S GLOW
, YO
U ARE
O
VERFIR
ING – IMM
ED
IATEL
Y TU
RN
OFF
TH
ER
MO
ST
AT
AN
D
ENSU
RE PRIM
AR
Y S
HUTTER
FIR
ING
AND
AS
HPIT DOO
R ARE
CLOSED.
CA
UTION
: MAIN
TA
IN
CO
MB
USTION
AIR
SU
PPL
Y T
O BOT
H F
URNACES
. AIR ST
AR
VA
TION I
S DANG
EROU
S (SEE
MANUAL
UN
DE
R “
OUT
SIDE
CO
MBUS
TIO
N AIR”
.
THE HM
F150
FURNAC
E MA
Y B
E CO
NNE
CTED T
O D
UCT
WORK (S
UP
PLY
SIDE
– S
EE
MANUAL)
OF
ANO
THER
FURN
ACE
WHEN US
ED
AS AN
WOOD
FUR
NAC
E “A
DD-O
N”.
CE
RT
IFIED FO
R SERIES CO
NN
EC
TION T
O T
HE SUP
PLY
PL
ENUM OUTLET
ONL
Y OF A
GAS FI
RE
D, OIL
FIRED,
OR ELECTRI
C FURNACE.
DO
NOT CON
NE
CT DUC
TWO
RK
SO
THA
T R
EVERSE F
LO
W IS
PO
SS
IBL
E.
FOR “
ADD ON”
INST
ALLA
TIO
N REFER
TO
MANUF
AC
TURES I
NSTRUCTION
S FROM
ORIGINA
L F
UR
NA
CE FOR IN
FORMAI
TO
N ON MINI
MUM D
UCT
SIZ
ING,
ALLOW
ABLE
DUCT
OP
ENINGS
IN FURNA
CE CASING
AN
D ELECTR
IC DIA
GRAM
S AND
INFOR
MA
TION
.
DO N
OT R
ELO
CA
TE
OR
BYP
ASS
AN
Y O
F THE
SA
FETY
CONTR
OL
S IN T
HE
ORIGINAL
FU
RNAC
E INST
ALLA
TION (“
AD
D ON” C
ON
FIGUR
ATION)
.
DO NOT
OBS
TRUCT
SP
ACE
UNDER F
UR
NACE.
UN
IT CA
N BE
INS
TA
LLE
D ON CO
MBUSTIBLE
SU
RF
AC
E (
WOO
D SUBS
TRA
TE
ONL
Y – C
ARP
ET
AND O
THER FLOO
R
COVERI
NGS T
O B
E REMOVED) P
ROVIDING
EMBER
ST
OP S
HIELD (S
EE
MAN
UAL) IN
ST
ALLE
D BE
TWEE
N FUR
NAC
E AND FLO
OR A
ND MINIM
UM 1
1/4” AIR
GAP
MA
INT
AIN
ED BE
TWE
EN
FU
RN
AC
E A
ND
FLO
OR.
INCASE
OF PO
WER
FA
ILURE: P
US
H DOWN
ON
TH
E C
ON
TROL
ARM
OF
THE PRIMA
RY A
IR CON
TR
OL
AND
LO
CK IT
DO
WN
USIN
G ROT
AT
ING
CLASP
. TO
AVO
ID
EXCESSIVE
HE
AT
BE
ING TR
APP
ED
IN
DU
CT
WOR
K E
NS
URE
ALL
RET
URN
AND
SUP
PLY
AIR REGIS
TE
RS
ARE NOT
BLO
CK
ED
BY
OBJE
CTS O
R DE
BRI
S AND ALL
DU
CT
CO
NT
ROL
DAMPERS ARE
SET
OP
EN.
SEE M
ANUAL
FO
R OPER
ATION O
F W
OO
D FURNAC
E IF ELEC
TRICAL
POWER
HAS
BEE
N INTE
RRUPTE
D.
OPER
AT
E ORIG
INA
L F
UR
NA
CE
(EL
ECT
RIC, OIL, GA
S) OF
A “
AD
D ON”
CONFIGUR
AT
ION PE
RIO
DICALL
Y T
O ENSUR
E IT
WI
LL O
PE
RAT
E SA
TISF
AC
TORI
LY WH
EN
NEEDE
D.
THE
HEA
T EX
CHANGER, FLUE PIPE
AN
D CHIM
NE
Y MUS
T B
E I
NS
PE
CTE
D F
RE
QUEN
TLY
AN
D CL
EA
NED
REGU
LA
RL
Y T
O R
EM
OVE ACCUM
ULA
TED
CREOS
OTE
AND
AS
H. UND
ER C
ERT
AIN
COND
ITI
ONS OF
US
E, C
RE
OS
OT
E BUI
LD
UP
MA
Y OC
CUR
RAPIDL
Y. EN
SU
RE THA
T TH
E H
EA
T EX
CHANGER, FL
UE PI
PE A
ND CHIMNE
Y AR
E
CLE
ANED
AT
EN
D OF B
URN
ING
SE
AS
ON,
TH
IS HE
LPS
TO
MI
NIM
IZE C
ORRO
SIO
N IN
TH
E SUMME
R MO
NTHS. T
HE APPLI
ANCE, F
LUE PIPE
AN
D CH
IMN
EY
MUST
BE
MAI
NT
AINE
D IN
GOO
D CONDITION. U
NS
AF
E TO
FI
RE W
ITH WOO
D AB
OV
E TO
P O
F R
EFRACT
ORY B
RICK
INSID
E COMBU
ST
IBL
E CHAMBER.
USE S
UP
PLY
WIRES S
UIT
ABLE FOR 1
67°F/75°C.
SEE INST
RUCTI
ON MA
NUA
L FOR E
LEC
TR
ICAL
DIA
GR
AM.
DA
NGER
: RISK
OF
EL
EC
TR
ICAL
SHOCK
. DISCONNEC
T POWER B
EFORE
SER
VICI
NG
UN
IT.
FO
R MOR
E I
NFORM
AT
ION REF
ER T
O O
WNER’
S M
ANUAL.
CAUT
IO
N
: TWO SOURC
ES OF EL
ECTRICAL
ENERGY
PRE
SE
NT I
N E
LE
CTR
IC FURNACE MO
DU
LE
- DISC
ONNE
CT
220V S
UP
PLY
TO
MO
DU
LE
AND 120V
SU
PP
LY
TO
HMF1
50
FURNACE B
EFORE SE
RV
ICI
NG
.
RE
PLACE ALL
CRA
CKE
D O
R BROK
EN
FIRE
BRIC
K AN
D TO
P B
AFF
LES. REPL
ACE
GLA
SS O
NL
Y WITH CE
RAMI
C GLA
SS
.
AUTHOR
IZE
D MO
DU
LES FOR
CON
NE
CTIO
N TO
HMF150
FUR
NACE
: BLOWER
BOX
MO
DULE
-
HMFK-
BMP
33
, ELECT
RIC
FURN
ACE MO
DU
LE-
HMFK
-EF2
0,
OIL
FURN
AC
E
MODU
LES
-
HMF
K-O
FR
F40
,
HMF
K-
OFA
FG
,
DHW
PRE
HEA
T MO
DULE
-
HMF
K-DHW
,
“AD
D ON” KI
T -
HM
FK
-A
DDO
N
THESE ARE
THE O
NL
Y AUT
HORIZED COM
PONENTS TH
AT
MA
Y BE
ATT
AC
HED T
O THE
HMF150
FURN
ACE
AS
IDE FROM
CO
NN
ECTIO
N TO
FO
RCED
AIR
SY
STEM
RETURN
AND
SUPPL
Y PLEN
UMS
. MODULE
S MUST
BE IN
ST
ALLE
D TO
MAN
UF
ACT
URERS INSTRU
CT
ION
S PO
STED
IN
TH
E I
NST
ALLA
TION
/OWNE
RS
MANUAL
ACC
OMP
A-
NYING HM
F150
AND
INS
TRUC
TION A
DDE
NDUM
S IN
CLUDE
D WIT
H EAC
H MO
DULE
.
HMF
150
CO
NFIG
UR
ED AS
AN
“ADD
ON
”:
MA
Y BE
ADDED
ON
TO
A F
UR
NAC
E HA
VING
A RA
TIN
G AS
SHOW
N O
N TH
E ORIGINA
L NAM
E PLA
TE BETW
EEN:
15 KW
MINIMUM
AN
D 2
0 KW M
AXIMUM
FOR
EL
ECTRI
C FU
RNA
CE
0.4
MI
NIMUM AND
0.7
1 MA
XIMUM
USG
PH
FOR
OIL
FU
RN
ACE
INPU
T
80,00
0 MAXI
MU
M BTU/
H FOR GAS FU
RNACE
INPUT
REFER T
O O
WNERS MA
NUA
L
WOLF S
TEEL
LTD.
24 NAP
OL
EO
N ROAD
, BARRI
E, ON,
L4
M
4Y
8 CANA
DA
18”
MA
X 1
6”
CL
EA
RA
N
CE
T
O
C
O
M
BU
SI
BL
ES
SE
RV
IC
E
CL
EA
RA
N
CE
24”
14”
CL
EA
RA
N
CE
T
O
C
O
M
BU
SI
BL
ES
SE
RV
IC
E
CL
EA
RA
N
CE
24”
LEF
T HA
ND
RA
CON
FIGUR
ATIO
N (R
EAR
VIE
W)
M
IN
IM
U
M
4
0”
18”
14”
M
IN
IM
U
M
5
2”
9”
*Dr
awi
ng
not
to
sca
le
O
IL
F
U
R
N
A
C
E
F
L
U
E
WOOD
, WOO
D/O
IL F
LUE
NOTE
:
RE
FER T
O MANU
AL
FO
R R
IGH
T H
AN
D C
ON
FIGU
RA
TION CL
EA
RANCE T
O COMB
US
TIBLES.
THE EL
ECTRI
C FURNAC
E MODUL
E (
NOT
SH
OW
N) F
ALLS
W
ITH
IN ENV
ELOP
E OF
CL
EARANC
E TO
COMBUSTIBLES
FOR
WOOD,
WOO
D/O
IL CONF
IGURA
TIO
N - THE
CLE
ARAN
CE
ENVE
LOPES
DO
NO
T
CHAN
GE WIT
H A
DDI
TIO
N OF
TH
E EL
EC
TRIC
FUR
NACE.
CL
EA
RA
N
CE
T
O
C
O
M
BU
ST
IB
LE
S
CLEA
RAN
CE T
O C
OM
BUS
TIBLE
S
48”
18”
24”
1.25”
CL
EA
RA
N
CE
T
O
C
O
M
BU
ST
IB
LE
S
SE
RV
IC
E
CL
EA
RA
N
CE
LEFT
HA
ND
RA C
ON
FIGU
RAT
ION
(SID
E VIE
W BL
OW
ER M
OD
ULE)
9”
*Dr
aw
ing
not
to scale
O
IL
F
U
RN
AC
E
FL
U
E
WO
OD,
WO
OD/
OIL
FLU
E
NOT
E:
SEC
TION “
C”
CLEARANC
ES M
AY
BE R
EDUC
ED
TO
0.
375
” B
EY
OND
A BEND
OR
OFFS
ET
IN
THE
DUC
T S
UFFICI
ENTL
Y L
ARGE T
O S
HIE
LD TH
E RE
MA
IN
DE
R OF
THE SUPPL
Y D
UC
T FROM
DIREC
T RAD
IATIO
N FR
OM
THE FURNA
CE
HEA
T
EX
CHANGER.
72”
1”
6”
7
f
t.
M
IN
IM
U
M
C
E
IL
IN
G
H
E
IG
H
T
CL
EA
RA
NC
E TO
CO
MBUS
TIB
LES
40”
>72”
A
B
C
NOT
E:
See
CAN/C
SA
-
B365
.01
and
NFP
A211 f
or
cle
aran
ce
to
co
mbusti
ble
spe
cific
ati
ons
for r
etur
n ai
r
duc
ting
.
*Draw
ing
not
to sc
ale
CLEAR
ANCE
TO
COMBUS
TIB
LE
S
SE
CTI
ON
A
B
C
TOP
6”
6”
1”
BOT
TOM/
SID
ES
18”
6”
1”
SERI
AL
NO.
HMF150
MANUF
ACT
URE DA
TE
:
JAN
AP
R
JUL
OCT
FEB
MA
Y
AUG
NOV
MA
R
JUN S
EP
DE
C
2010
201
1 2012 20
13
Une prise d'air de 4" peut être installée à l'arrière de la fournaise HMF150 de Napoléon pour l'alimenter
directement en air comburant. Cette prise d'air peut fournir de l'air comburant uniquement à la fournaise à
bois HMF150.
Fixez et scellez les gaines de prise d'air aux collets à l'aide de 3 trois vis autoperceuses et du scellant à haute
température.
Dans les climats plus froids, il est conseillé d'isoler les gaines de prise d’air a
fi
n d'empêcher la condensation.
La prise d'air de 4 " peut aussi aspirer l'air comburant de la pièce, pourvu que l'apport d'air soit suf
fi
sant.
Dans le cas des fournaises à l'huile, la prise d'air frais doit être installée par un technicien en chauffage à
l'huile quali
fi
é, conformément aux normes d'installation CSA B139-09 « Code d'installation des appareils
alimentés à l'huile ».
L’alimentation en air frais des fournaises au gaz doit être conforme aux normes CAN/CGA-B149.1 ou
CAN/CGA-B149.2.
L’alimentation en air frais pour les fournaises à combustible solide doit respecter la norme CAN/CSA-B365.
LORS DE L'INSTALLATION D'UN SYSTÈME D'APPORT D'AIR FRAIS, L'INSTALLATEUR DOIT
PRÉVOIR UN APPORT D'AIR SUFFISANT DANS L'ÉVENTUALITÉ OÙ PLUS D'UNE FOURNAISE,
INTÉGRÉES DANS UNE CONFIGURATION MULTIPLE, FONCTIONNERAIENT SIMULTANÉMENT.
!
AVERTISSEMENT
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...