All plenum and ducting clearances must satisfy speci
fi
cation set forth in CAN/CSA-B365.01 and NFPA211.
72”
1”
6”
7 f
t. MINIMUM CEILING HEIGHT
40”
>72”
A
B
C
NOTE:
See
CAN/CSA-
B365.01 and
NFPA211 for
clearance to
combustible
specifications
for return air
ducting.
CLEARANCE TO COMBUSTIBLES
*Drawing not to scale.
6.3 GENERAL PLENUM AND DUCTING - CLEARANCE TO COMBUSTIBLES
CLEARANCE TO
COMBUSTIBLES
SECTION
A
B
C
TOP
6”
6”
1”
BOTTOM/SIDES
18”
6”
1”
○
Separate chimneys are required when connecting the HMF150 to a pre existing natural gas or propane
furnace.
6.4 FLUE CONFIGURATION FOR "ADD ON" FURNACE CONFIGURATION
UNDER NO CONDITIONS MAY A SOLID FUEL BURNING APPLIANCE SHARE A CHIMNEY THAT
VENTS NATURAL GAS OR PROPANE EXHAUST.
DO NOT USE MAKESHIFT COMPROMISES DURING INSTALLATION. DO NOT BLOCK OR RESTRICT
AIR. DO NOT IMPEDE AIR MOVEMENT ZONES MARKED “CLEARANCE TO COMBUSTIBLES”.
ALL PLENUM DUCTING AND VENTING INSTALLATION MUST CONFORM WITH CAN/CSA B365-
01, CSA B139-09, AND NFPA 211. ALWAYS CHECK LOCAL BUILDING AND FIRE CODES , AND
AUTHORITIES HAVING JURISDICTION.
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...