W415-0910 / A / 09.16.10
25
REQUIRED COMPONENTS:
• HMF150 Hybrid Furnace
• HMFK-BMP33 Blower Box Module
• HMFK-SOLID or HMFK-GLASS Door Kit
STEPS:
Completely assemble HMF150 in required left or right hand "RA" con
fi
guration as required.
STEP #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID
HMF150 AS A "ADD ON" TO EXISTING FURNACE.
STEP #5
○
Locate and level the HMF150 while maintaining
a minimum 1.25" clearance space between the
bottom of the furnace and
fl
oor.
○
Use levelling the legs to compensate for uneven
fl
oor and snug lock nuts up to the furnace base to
prevent movement through vibration.
○
Remove the contents of the blower module
kit and compare with the contents list on the
"Manual" addendum, accompanying the Blower
Module.
STEP #6
○
Place the blower box module with the blower
outlet side facing the rectangular opening on the
side panel.
○
Adjust the levelling legs on the blower box
module so that the module is level and clearance
hole on the mounting
fl
anges align with pilot holes
on side of the furnace panel.
STEP #7
○
Lift the blower exhaust side of blower box so as
to allow mounting
fl
ange on the bottom edge
of the blower box to clear the top edge of the
retaining bracket fastened to the lower edge of
the rectangular opening in the furnace side.
○
Slide the blower box in so the lower mounting
fl
ange of the blower box is contained between the
fl
ange of the retaining bracket and the furnace
side.
○
Fasten the sides and top mounting
fl
anges of the
blower box using wildrill 1/4" hex head screws.
THE INSTALLATION OF THE WOOD FURNACE / COMBINATION WOOD FURNACE MUST BE DONE IN
ACCORDANCE WITH RULES OF AUTHORITIES HAVING JURISDICTION AND THE CAN / CSA B365-01
(R2006) STANDARD FOR SOLID FUEL BURNING APPLIANCES AND EQUIPMENT.
2
1
3
4
LEVEL LEG
LOCK NUT
RETAINING FLANGE
ITE
ITEM
DESCRIPTION
DESCRIPTION
QT
QTY
1 HMF150 HYBRID FURNACE
HMF150 HYBRID FURNACE
1
2 HMFK-BMP33 BLOWER BOX MODULE
HMFK-BMP33 BLOWER BOX MODULE
1
3 1/4" HEX HEAD WILDRIL SCRE
1/4" HEX HEAD WILDRIL SCREW
11
11
4 HMFK - SOLID or HMFK - GLASS DOOR KIT
HMFK - SOLID or HMFK - GLASS DOOR KIT 1
5.2 HYBRID HMF150 AS A “STAND ALONE” WOOD FURNACE
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...