NOTE
The control of the "Add On" style installation is the same as the fore mentioned paragraph except for the
position of the selector toggle switch being redundant.
BOTH OIL AND ELECTRIC FURNACES HAVE RESET CONTROLS AND PROCEDURES REQUIRED
TO RESTART THE UNITS IF A FAULT HAS BEEN DETECTED AND UNITS LOCKED OUT. ONLY A
QUALIFIED INSTALLER/SERVICE PERSON SHALL PERFORM THESE RESET PROCEDURES AS A
CAUSE AND REPAIR MUST BE DETERMINED BEFORE THE UNIT CAN BE RESTARTED. FAILURE TO
FOLLOW THIS STEP COULD RESULT IN PROPERTY DAMAGE, INJURY OR DEATH.
SERVICE PERSONS CAN FIND TROUBLESHOOTING AND RESET PROCEDURE IN THE MANUALS
ACCOMPANYING BOTH THE ELECTRIC FURNACE AND OIL BURNER MODULES.
8.3 CONTROL SYSTEM - SUMMER FAN
○
A summer fan switch has been added to the main electric control box. This will provide low speed air
circulation during the summer time when the furnace is not being used. Depress rocker switch to “Summer
Fan” position, thw switch will light and the fan will run.
ENSURE THE SUMMER SWITCH REMAINS IN THE "OFF" POSITION DURING THE HEATING
SEASON. FAILURE TO COMPLY WITH THIS WILL RESULT IN EXCESSIVE CHILLING OF THE
EXHAUST PRODUCTS AS THEY PASS THROUGH THE EXCHANGER PIPES, THE FURNACE FLUE
AND THE CHIMNEY SYSTEM. THIS CHILLING WILL RESULT IN THE CONDENSATION OF EXHAUST
PRODUCTS IN THE EXCHANGER AND CHIMNEY RESULTING IN CREOSOTE BUILD UP. THE
CREOSOTE BUILD UP WILL RESULT IN REDUCED EFFICIENCIES OF THE EXCHANGER TUBES AND
SUBSTANTIALLY INCREASES THE RISK OF A CHIMNEY FIRE.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
8.4 OPERATING SOUNDS AND SMELLS
When
fi
rst installed, the furnace brick and metal are cold and must become hot before the appliance will
function well. During the break-in period (the
fi
rst 2 or 3
fi
res) create only small, hot
fi
res using kindling; this will
allow the
fi
rebrick to cure. Do not be alarmed if small hairline cracks develop in the
fi
rebrick. This is a normal
occurrence and does not pose a safety hazard. The paint may also smell a little for the
fi
rst few
fi
res as it
cures and you may wish to open a door or window to alleviate the smell.
There are many different ways to start a
fi
re, review the hints and warnings in this section to ensure the
fi
re is
started properly.
Summary of Contents for HYBRID 150
Page 6: ...W415 0910 A 09 16 10 6 AIR FLOW CIRCULATION AND HEAT TRANSFER COMBUSTION AIR FLOW...
Page 64: ...W415 0910 A 09 16 10 64 13 0 SERVICE HISTORY...
Page 65: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 66: ...W415 0910 A 09 16 10 66 14 0 NOTES...
Page 72: ...W415 0910 A 09 16 10 6 CIRCULATION D AIR ET CHANGE DE CHALEUR CIRCULATION DE L AIR COMBURANT...
Page 131: ...W415 0910 A 09 16 10 65 14 0 NOTES...
Page 132: ...W415 0910 A 09 16 10 66 14 0 NOTES...