FP
Σ
Communication Function 2 General-purpose Serial Communication
9 - 18
Communication format setting for Micro-Imagechecker
To set the communication mode and transmission format settings for the Micro-
Imagechecker, select “5: Communication” under “5: ENVIRONMENT” on the main
menu, and set the following items.
No.
Name
Set value
No. 51
Communication mode
Normal Mode
No. 52
RS232C
Baud rate
9600 bps
. . . . . . . . . . .
Length
8
. . . . . . . . . . . . .
Stop bit
1
. . . . . . . . . . . .
Parity
Odd
. . . . . . . . . . . . . .
Flow Control
None
. . . . . . . .
Serial communication setting for Micro-Imagechecker
To enter settings relating to serial communication for the Micro-Imagechecker, select
“53: Serial Output” under “5: Communication” on “5: ENVIRONMENT” of the main
menu, and set the following items.
No.
Name
Set value
No. 53
Serial Output
Output
5 Column
. . . . . . . . . . . . . .
Invalid Digit
Repl. 0
. . . . . . . . . .
Read End
None
. . . . . . . . . . .
Process End
None
. . . . . . . . .
Numerical Calculation Output
.
Judgment
Output
. . . . . . . . . . .
- If “Del” is specified for the invalid processing parameter, zero suppression
processing will be carried out on the output data, and the output format will be
changed. Always make sure “Repl. 0” is specified.
- When outputting data to an external device, numerical calculation is required, so
“Out” should be specified for the “Numerical calculation” parameter.
- When the above settings are specified, data with the contents shown below will
be output from the Micro-Imagechecker.
Tip
CR
1 0 1 2 3 4 5
Terminator (End code)
Results of numerical calculation No.1
Judgment output No.2 0=NG
Judgment output No.1 1=OK
Summary of Contents for FP Series
Page 15: ...FP Functions and Restrictions of the Unit 1 2...
Page 25: ...FP Specifications and Functions of Control Unit 2 2...
Page 37: ...FP Expansion 3 2...
Page 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Page 45: ...FP I O Allocation 4 2...
Page 51: ...FP Installation and Wiring 5 2...
Page 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Page 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Page 135: ...FP Communication Cassette 7 2...
Page 147: ...FP Communication Function 1 Computer Link 8 2...
Page 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Page 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Page 207: ...FP Communication Function 3 PLC Link Function 10 2...
Page 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Page 233: ...FP Other Functions 11 2...
Page 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Page 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Page 251: ...FP Specifications 13 2...
Page 323: ...Index FP I 4...
Page 325: ...FP Record of changes R 2...