FP
Σ
Specifications
13 - 24
Relay No.
Name
Description
R9030
Not used
R9031
Not used
R9032
COM. 1 port communication
mode flag
This is on when the general-purpose communication function is
being used.
It goes off when the MEWTOCOL-COM or the PLC link function is
being used.
R9033
Print instruction execution flag Off: Printing is not executed.
On: Execution is in progress.
R9034
Run overwrite complete flag
This is the special internal relay that goes on for only the first scan
following completion of a rewrite during the RUN operation.
R9035
Not used
R9036
Not used
R9037
COM.1 port communication
error flag
This goes on if a transmission error occurs during data
communication.
This goes off when a request is made to send data, using the
F159
(MTRN)
instruction.
R9038
COM.1 port reception done
flag during general purpose
communicating
Turns on when the end code is received during the general purpose
communicating.
R9039
COM.1 port transmission
done flag during general
purpose communicating
This goes on when transmission has been completed when using
general-purpose communication.
It goes off when transmission is requested when using general-
purpose communication.
R903A
High-speed counter
control flag
ch0
Turns on while the high-speed counter instructions
F166 (HC15)
,
F167 (HC1R)
and the pulse output instructions “
F171 (SPDH)
to
F176 (SPCH)
” are executed.
R903B
High-speed counter
control flag
ch1
Turns on while the high-speed counter instructions
F166 (HC15)
,
F167 (HC1R)
and the pulse output instructions “
F171 (SPDH)
to
F176 (SPCH)
” are executed.
R903C
High-speed counter
control flag
ch2
Turns on while the high-speed counter instructions
F166 (HC15)
,
F167 (HC1R)
and the pulse output instructions “
F171 (SPDH)
to
F176 (SPCH)
” are executed.
R903D
High-speed counter
control flag
ch3
Turns on while the high-speed counter instructions
F166 (HC15)
,
F167 (HC1R)
and the pulse output instructions “
F171 (SPDH)
to
F176 (SPCH)
” are executed.
R903E
Not used
R903F
Not used
Summary of Contents for FP Series
Page 15: ...FP Functions and Restrictions of the Unit 1 2...
Page 25: ...FP Specifications and Functions of Control Unit 2 2...
Page 37: ...FP Expansion 3 2...
Page 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Page 45: ...FP I O Allocation 4 2...
Page 51: ...FP Installation and Wiring 5 2...
Page 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Page 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Page 135: ...FP Communication Cassette 7 2...
Page 147: ...FP Communication Function 1 Computer Link 8 2...
Page 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Page 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Page 207: ...FP Communication Function 3 PLC Link Function 10 2...
Page 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Page 233: ...FP Other Functions 11 2...
Page 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Page 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Page 251: ...FP Specifications 13 2...
Page 323: ...Index FP I 4...
Page 325: ...FP Record of changes R 2...