FP
Σ
13.8 Table of Instructions
13 - 61
No.
Name
Boolean Operand Description
Steps
Integer type data processing instructions
F270 Maximumvalue
(word data
(16-bit))
MAX
S1, S2, D
Searches the maximum value in the word data table
between the “S1” and “S2”, and stores it in the “D”. The
address relative to “S1” is stored in “D+1”.
8
F271 Maximumvalue
(double word
data (32-bit))
DMAX
S1, S2, D
Searches for the maximum value in the double word
data table between the area selected with “S1” and
“S2”, and stores it in the “D”. The address relative to
“S1” is stored in “D+2”.
8
F272 Minimum value
(word data
(16-bit))
MIN
S1, S2, D
Searches for the minimum value in the word data table
between the area selected with “S1” and “S2”, and
stores it in the “D”. The address relative to “S1” is
stored in “D+1”.
8
F273 Minimum value
(double word
data (32-bit))
DMIN
S1, S2, D
Searches for the minimum value in the double word data
table between the area selected with “S1” and “S2”, and
stores it in the “D”. The address relative to “S1” is stored
in “D+2”.
8
F275 Total and mean
values (word
data (16-bit))
MEAN
S1, S2, D
The total value and the mean value of the word data
with sign from the area selected with “S1” to the “S2”
are stored in the “D”.
8
F276 Total and mean
values (double
word data
(32-bit))
DMEAN
S1, S2, D
The total value and the mean value of the double word
data with sign from the area selected with “S1” to “S2”
are stored in the “D”.
8
F277 Sort (word data
(16-bit))
SORT
S1, S2, S3 The word data with sign from the area specified by “S1” to
“S2” are sorted in ascending order (the smallest word is
first) or descending order (the largest word is first).
8
F278 Sort (double
word data
(32-bit))
DSORT
S1, S2, S3 The double word data with sign from the area specified
by “S1” to “S2” are sorted in ascending order (the
smallest word is first) or descending order (the largest
word is first).
8
F282 Scaling of
16-bit data
SCAL
S1, S2, D
The output value “Y” is found for the input value “X” by
performing scaling for the given data table.
8
F283 Scaling of
32-bit data
DSCAL
S1, S2, D
The output value “Y” is found for the input value “X” by
performing scaling for the given data table.
10
F285 16-bit data
upper and
lower limit
control
LIMT
S1, S2,
S3, D
When S1 S3, S1
→
D
When S2 S3, S2
→
D
When S1 S3 S2, S3
→
D
10
F286 32-bit data
upper and
lower limit
control
DLIMT
S1, S2,
S3, D
When (S1+1, S1) (S3+1, S3), (S1+1, S1)
→
(D+1, D)
When (S2+1, S2) (S3+1, S3), (S2+1, S2)
→
(D+1, D)
When (S1+1, S1) (S3+1, S3) (S2+1, S2), (S3+1, S3)
→
(D+1, D)
16
F287 16-bit data
deadband
control
BAND
S1, S2,
S3, D
When S1 S3, S3 - S1
→
D
When S2 S3, S3 - S2
→
D
When S1 S3 S2, 0
→
D
10
F288 32-bit data
deadband
control
DBAND
S1, S2,
S3, D
When (S1+1, S1) (S3+1, S3),
(S3+1, S3) - (S1+1, S1)
→
(D+1, D)
When (S2+1, S2) (S3+1, S3),
(S3+1, S3) - (S2+1, S2)
→
(D+1, D)
When (S1+1, S1) (S3+1, S3) (S2+1, S2),
0
→
(D+1, D)
16
Summary of Contents for FP Series
Page 15: ...FP Functions and Restrictions of the Unit 1 2...
Page 25: ...FP Specifications and Functions of Control Unit 2 2...
Page 37: ...FP Expansion 3 2...
Page 44: ...Chapter 4 I O Allocation 4 1 I O Allocation 4 3...
Page 45: ...FP I O Allocation 4 2...
Page 51: ...FP Installation and Wiring 5 2...
Page 77: ...FP High speed Counter and Pulse Output Functions 6 2...
Page 133: ...FP High speed Counter and Pulse Output Functions 6 58...
Page 135: ...FP Communication Cassette 7 2...
Page 147: ...FP Communication Function 1 Computer Link 8 2...
Page 169: ...FP Communication Function 2 General purpose Serial Communication 9 2...
Page 205: ...FP Communication Function 2 General purpose Serial Communication 9 38...
Page 207: ...FP Communication Function 3 PLC Link Function 10 2...
Page 232: ...Chapter 11 Other Functions 11 1 Analog Potentiometer 11 3 11 2 Clock Calendar Function 11 4...
Page 233: ...FP Other Functions 11 2...
Page 239: ...FP Self Diagnostic and Troubleshooting 12 2...
Page 249: ...FP Self Diagnostic and Troubleshooting 12 12...
Page 251: ...FP Specifications 13 2...
Page 323: ...Index FP I 4...
Page 325: ...FP Record of changes R 2...