Model-related data (basic design)
Description
10V1600
C60
10V1600
C70
Number of cylinders
10
10
Cylinder configuration: V angle
Degrees
(°)
90
90
Bore
mm
122
122
Stroke
mm
150
150
Displacement of a cylinder
Liters
1.75
1.75
Total displacement
Liters
17.5
17.5
Number of inlet valves per cylinder
2
2
Number of exhaust valves per cylinder
2
2
Combustion air / exhaust gas
Description
10V1600
C60
10V1600
C70
Charge-air pressure before cylinder under standard conditions
and at a site altitude of 400 m above sea level
R
bar abs.
3.8
3.84
Exhaust gas temperature after exhaust turbocharger under stand-
ard conditions and at a site altitude of 400 m above sea level
R
°C
376*
422*
Coolant system (HT circuit)
Description
10V1600
C60
10V1600
C70
Coolant temperature (at engine connection: outlet to cooling
equipment)
A
°C
95
95
Coolant temperature after engine, limit 1
L
°C
107
107
Coolant temperature after engine, limit 2
L
°C
118
118
Coolant antifreeze content, max.
L
%
55
55
Coolant pump: Inlet pressure, max.
L
bar
2.5
2.5
Thermostat: Starts to open
R
°C
79
79
Thermostat: Fully open
R
°C
92
92
Coolant system (LT circuit)
Description
10V1600
C60
10V1600
C70
Coolant antifreeze content, max.
L
%
55
55
Charge-air temperature charge-air cooler, max.
L
°C
90
90
Thermostat: Starts to open
R
°C
30
30
Thermostat: Fully open
R
°C
45
45
Lube oil system
Description
10V1600
C60
10V1600
C70
Lube oil operating temperature before engine, from
R
°C
112
112
Lube oil operating temperature before engine, to
R
°C
122
122
MS150100/06E 2017-08
| Technical Data | 35
TIM-ID: 0000054314 - 003