Note:
Do
not fully unscrew threaded vent plug.
3.
Open threaded vent plug (arrowed).
4.
Operate the pump with the handle until bub-
ble-free fuel emerges from the threaded vent
plug (arrowed).
5.
Screw in threaded vent plug (arrowed) and tighten to specified torque using a torque wrench.
Name
Size
Type
Lubricant
Value/Standard
Screw
10
Tightening torque
6.5 Nm ±1.3 Nm
112 | Fuel System | MS150100/06E 2017-08