1422 – AL Flap Bypass A blocked drive
Cause
Corrective action
The mechanism of the bypass flap
A side (M52.1) is blocked.
1. Check smooth operation of the exhaust flap mechanism.
2. Contact Service.
1423 – AL Flap Bypass B blocked drive
Cause
Corrective action
The mechanism of the bypass flap
B side (M52.2) is blocked.
1. Check smooth operation of the exhaust flap mechanism.
2. Contact Service.
1430 – AL Act Agr A Temperature Alert
Cause
Corrective action
The internal servomotor
electronics of the EGR shutoff flap
A side (M53.1) signal excessively
high temperature.
1. Check for high temperatures in the vicinity of the servomotor, e.g.
resulting from faulty insulation, defective seals, signs of sooting
(→ Page 119).
2. Contact Service.
1431 – AL Act Agr B Temperature Alert
Cause
Corrective action
The internal servomotor
electronics of the EGR shutoff flap
B side (M53.2) signal excessively
high temperature.
1. Check for high temperatures in the vicinity of the servomotor, e.g.
resulting from faulty insulation, defective seals, signs of sooting
(→ Page 119).
2. Contact Service.
1432 – AL Act Byp A Temperature Alert
Cause
Corrective action
The internal servomotor
electronics of the bypass flap A
side (M52.1) signal excessively
high temperature.
1. Check for high temperatures in the vicinity of the servomotor, e.g.
resulting from faulty insulation, defective seals, signs of sooting
(→ Page 119).
2. Contact Service.
1433 – AL Act Byp B Temperature Alert
Cause
Corrective action
The internal servomotor
electronics of the bypass flap B
side (M52.2) signal excessively
high temperature.
1. Check for high temperatures in the vicinity of the servomotor, e.g.
resulting from faulty insulation, defective seals, signs of sooting
(→ Page 119).
2. Contact Service.
1436 – AL Act Agr A Voltage Supply
Cause
Corrective action
The servomotor supply voltage for
the EGR shutoff flap A side
(M53.1) is below 9 V or above
32 V. The servomotor assumes a
safe position.
1. Check state of battery charge (plant).
2. Check plug connections to engine governor (→ Page 159).
3. Contact Service.
100 | Troubleshooting | MS150100/06E 2017-08