Page 66 MSI-3750CS RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
@I
OUTPUT RF MODEM ID
Use the @I command to print the RF Modem ID numbers of the connected CellScale and the internal
3750CS modem.
Input Data Form:
@I1
Print CellScale Modem ID# (0-255) of connected Master CellScale
@I2
Print Modem ID (MY ID) of this 3750CS
Output Data Form:
@I1
CS ID #xxx
Length: 9 Justification: right, leading zeros not suppressed
@I2
MY ID #xxx
Length: 9 Justification: right, leading zeros not suppressed
@L
PRINT ID CODE STRINGS
Use the @L command to print one or both of the ID Code Strings. ID Code Strings will change as the ID
code number is changed. ID Code Strings can include text, numbers, and control codes thereby allowing the
printer format or text to change with the ID Code.
Input Data Form:
@L1
Print ID Code String 1
@L2
Print ID Code String 2
Output Data Form:
Depends on user entered Strings. Up to 20 bytes unless “@” codes are embedded, which could increase the
length of data generated by this command.
Caution
: Do not embed an “@L” command inside the ID String as this will cause an endless loop.
@M
PRINT WEIGHING MODE
Use the @M command to print either the current weighing mode or print the internal mode strings.
Input Data Form:
@M1
Print Current Display Mode
@M2
Print “GROSS”
@M3
Print “NET”
@M4
Print “TARE”
@M5
Print “TOTAL”
@M6
Print “T CNT” (Total CouNT= number of weighments totaled)
@M7
Print “TOTAL T CNT”
@M8
Print lower display Mode
@M9
Print “GROSS+” or “NET+” or “AD2TOT” depending on the last totaled
weight mode.
Output Data Form:
@M1
* * * * * *
Length: 8 or 9 with DP. Justification: left
*****
= Lower display
@M2
G R O S S
Length: 6 Justification: left
@M3
N E T
Length: 6 Justification: left
@M4
T A R E
Length: 6 Justification: left
@M5
T O T A
L