Page 36 MSI-3750CS RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
VIEW TOTAL
Displays the current Total value of the selected ID and allows the total(s) to be cleared.
The following examples assume the F4 function key is programmed to “VIEW TOTAL”. If the VIEW TOTAL key has been moved to a different F key use
that key for the following procedure.
To Display the Current ID#’s Totaled Weight
To Enable/Disable Total Motion Detect
Push VIEW TOTAL (Usually F4). The numeric
display shows the accumulated weight. The message
display indicates the number of weighments in the
Total. This screen will remain for 4 seconds.
1
2
∑ MODE
3
∑ MOTION
4
ENABLED
5
DISABLED
6
∑ MOTION
7
1) Push SETUP.
2) Push the TOTAL switch (usually F3). The menu
choice “
∑
MODE” appears.
3) Push the UP key to the menu choice
“
∑
MOTION”.
4) Push ENTER. The message display shows
“ENABLED” or “DISABLED”.
5) Toggle the motion condition with the UP or DOWN
key.
ENABLED means totals will not function until the weight has settled.
DISABLED indicates that motion conditions are ignored.
6) Set the new Total Motion condition by pushing
ENTER.
7) Push the EXIT key to return to normal scale
operation.
To Erase the last Totaled Weight
If the last totaled (automatic or manual) weighment was a mistake, it can be erased with the following procedure. This erases only the last weighed value.
1
1
2
1) Push VIEW TOTAL (Usually F4) followed imme-
diately by CLR (ZERO).
The display reads “CLRLAST
∑
”.
2) Press ENTER. The last weight totaled is subtracted
and the number of weighments counter is reduced
by one.
If you change your mind, push EXIT to cancel the Clear Last Total
operation.
1
2
1) Push
VIEW TOTAL
(usually F4) followed quickly
by the (2) PRINT key. Just the Total and number of
samples of the current ID will print.
To Print the Current ID#’s Totaled Weight