MSI-9000 CellScale
®
System • 3750CS User Guide Page 23
MEASUREMENT SYSTEMS INTERNATIONAL
Software V1-15 to 1-20
value than previously recorded is detected.
To Clear Peak Weight Readings
Turn off the Peak mode by pushing the
FUNCTION
key programmed as “PEAK HOLD”. The 3750CS reads
“PEAK OFF” and clears the peak value from memory. The display will revert to NET or GROSS mode.
Peak Hold captures data at a reading rate set up by the CellScale A/D parameters. For High Speed Peak Hold, use a faster A/D rate. See CellScale Manual.
Sends the current displayed reading to the Comm Port, unless otherwise setup in the Print Setup menu .
Any or all weight, time, date, and scale parameter functions can be printed as set in the Print Setup Mode.
Refer to Section 9 for more details.
TEST
Provides a functional system test, and an on-demand display check without disturbing the current weighment.
The Test function can be interrupted by pushing any key during the test.
The TEST function is also available as a FUNCTION key choice. See “FUNCTION Keys” Section 4.
Test Meter Operation
1
2
Final: Either the reading returns to the pre-test condition, or an
error message is displayed.
1) Push the SETUP key.
2) Push the 9 key.
a) All segments turn on for 1 second, the off for 1/2
second.
b) All digits (7 segment and 16 segment) count once
from 0 to 9. All annunciators are tested including
lb., kg, t. and the Total LED.
c) Battery condition is displayed next in the form: %
of Battery life with a figure from 1 to 100 on the
digits. The % battery life will vary depending on
whether the backlight is on or off.
ACTIVATE & DEACTIVATE CHANNELS
In systems with large channel scan lists, it is sometimes useful to be able to deactivate a channel that is
not in use without losing calibration for that channel. This also improves data flow since no time is spent
converting inactive channels.
1
2
SC INDEX
3
SC 2
STATUS
4
ACTIVE
5
INACTIVE
7
1) Push the SETUP key.
2) Push the F key programmed as “SC INDEX”.
3) Push Enter.
4) Use the UP/DOWN keys to scroll through all
available channels. To check or change the status,
push ENTER on the desired channel.
5) To change the status use the LEFT/RIGHT key.
The display will toggle between “ACTIVE” and
INACTIVE.
6) Repeat steps 4 and 5 for all channels.
7) Push EXIT once to return to scrolling through
channels, or push EXIT twice to return to normal
scale operation. All inactive channels will now
be skipped.