Page 72 MSI-3750CS-5 RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
Length: 10 Justification: right, leading zeros suppressed
@W8
1 2 3 4 5 6 7 8
Length: 10 Justification: right, leading zeros suppressed
@Y
PRINT STATISTICS FULLY
Use the @Y command to print the statistics of the current ID Code with text descriptor.
Input Data Form:
@Y1
Average weight
@Y2 Minimum weight
@Y3
Maximum weight
@Y4 Standard Deviation
@Y5
Coefficient of Variance (%)
@Y6 Grand Total
@Y7
Grand Average
@Y8 Grand Number of Samples
Output Data Form:
@Y1
1 3 . 3 5 5 K G A V G
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y2
3 . 2 1 0 K G M I N
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y3
2 0 . 0 1 5 K G M A X
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y4
2 0 . 0 1 5 K G S T D D E V
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y5
3 2 . 5 0 % C O . V A R
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y6
4 3 1 3 5 . 5 5 K G G – T O T L
Length: 22 Justification: Weight - right, Units - left, Mode - left
@Y7
4 . 3 2 7 K G G – A V G
Length: 20 Justification: Weight - right, Units - left, Mode - left
@Y8
1 2 3 4 5 6 G – C N T
Length: 14 Justification: Counts - right, Mode - left
@Z
PRINT ALL STATISTICS & GRAND TOTAL
Use the @Z command to print the statistics of all the ID Codes followed by the Grand Total Statistics.
Input Data Form:
@Z1
Print All without labels
@Z2
Print All with labels
Output Data Form:
The @Z Command combines data from all the Product Codes Statistics and prints them in a formatted form. This
output can be quite lengthy depending on the number of Product Codes in use. Only product codes that have at
least one Total weighment will print.
@#
DATA FROM SCALE CHANNEL #
Use the @# (where # = 0-31) commands in conjunction with the @Vx or @Wx commands to cause the print
string to take data from any scale channel listed in the Channel List. See the CellScale manual for information