Page 44 MSI-3750CS-5 RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
Follow a similar procedure for the Date entry. The Date is entered in the order MM DD YY. When finished setting
all the Clock / Calendar parameters, push EXIT three times to return to normal scale operation.
The week day is entered with the UP/DOWN keys. Use 01 for Sunday, 02 for Monday, 03 for Tuesday, 04 for
Wednesday, 05 for Thursday, 06 for Friday, and 07 for Saturday.
MODE
The MODE sets the display mode of the real-time Clock when the clock is enabled. Select “12HR/MIN” to display
the time in 12 hour format with hours, minutes, and a PM indication. Select “12HR/SEC” to display the time in
12 hour format with hours, minutes, seconds, and a PM indication. Select “24HR/MIN” for 24 hour indication
with hours and minutes. Select “24HR/SEC” for 24 hour indication with hours, minutes, and seconds.
CLOCK
Select “ENABLED” to turn the scale into a clock calendar when the power is not on. The Micro-processor wakes
up to update the display either every minute or every second depending on the mode selected. The processor
will also check for activity on the Comm Ports to see if a Power up command is received. Therefore to achieve
no worse than a 1 second turn on, set the mode to the 12HR/SEC or the 24HR/SEC selection. The mode has no
effect on the power switch.
Operating the Clock from a battery powered MSI 3750CS has very little effect on battery life. The LCD and LCD drivers use only minimal power. The µP is only
awake long enough to update the LCD so its average power consumption is small. Using the /MIN mode selections minimizes the µP power drain.
SETUP POWER MENU
Allows Front Panel entry of seldom set parameters involving power consumption.
AUTO OFF
POWER SRC MENU
PWR BATT
PWR VEHI
PWR AC
BACKLIGHT MENU
ON
AUTO
OFF
24 HOURS
8 HOURS
4 HOURS
2 HOURS
1 HOUR
30 MIN
10 MIN
DISABLED
AUTO OFF MENU
POWER SETUP
MENU
LIGHTING
AUTO OFF
EXIT
SETUP
!
POWER
POWER
The AUTO OFF feature when enabled prolongs the battery life of the scale by turning the power off after a set
time of non use. Depressing any key, or any change in the detected weight will reset the time limit . This feature
defaults to the disabled mode when initially calibrated. When disabled the scale will stay on, only the power key
(or Remote) will turn it off.
LIGHTING
A photocell detects ambient light and determines if the backlight should be on or off (AUTO mode). The “ON”
mode turns the backlight on full time. For decreased power drain, the “OFF” mode disables the backlight.