5-8
PMP320HDW2v1
Preliminary
JUL 2010
Attaching the CSM and mounting the bracket assembly outside the building
Chapter 5: CSM Hardware Installation
Procedure 5-3 Mounting bracket assembly (Continued)
6
Slide the bracket arm tab onto the bolt, and then place a flat washer over the
end of the bolt.
7
Tighten the end of the bolt with a hex nut. Leave the hex nut loose enough so
that the vertical tilt of the CSM can be adjusted later.
8
Attach the other end of the bracket arm to the second wall bracket.
9
Insert a 5/16×1½ hex bolt into the arch of the second wall bracket. This
bracket is attached to the wall or clamped to a pole.
NOTE
Ensure that the head of the hex bolt rests inside the bolt jam found
on the arch. When the assembly is complete, ensure that the bolt
jam is facing the ground.
10
Guide the rest of the bolt through the arch of the wall bracket.
11
Slide a tooth lock washer at the end of the hex bolt.
12
Align the hole on the tab of the bracket arm with the end of the bolt.
13
Slide the tab of the bracket arm onto the bolt, and then place a flat washer
over the end of the bolt.
14
Tighten the end of the bolt with a hex nut. Leave the hex nut loose enough so
that the horizontal tilt of the CSM can be adjusted later.
15
If fastening the CSM to a pole, loosely attach the clamp to wall bracket 2.
Perform the steps listed in the section Fastening the CSM and mounting the
bracket assembly to a pole.
Attaching the CSM and mounting the bracket assembly outside
the building
WARNING
Maintain a safe distance from RF exposure at least 120 cm when installing the CSM to
the subscriber building. Maintain safe distances from power lines.
Perform the following procedure to attach the CSM to the outside of the building.