3-44
PMP320HDW2v1
Preliminary
JUL 2010
6
On the door label, record the MAC and IP addresses of the CMM4 and all
connected equipment.
7
Record also the MAC address of the EtherWAN switch.
8
Consistent with practices in your company, note the above information to add
later to the company equipment database.
9
Connect the coax cable from the female N-connector on the GPS antenna to
the female N-connector on the outside of the CMM4.
10
Ensure there is an Ethernet cable between the management port on the
controller board and one of the Ethernet ports on the EtherWAN switch.
11
Feed the DC power cord through a cable gland. A 1-hole gland insert is
provided, as the DC power cable is too thick to share a gland with other
cables. The 1-hole insert is either connected to one of the patch cables or
included in the parts bag.
12
Connecting power to the terminal block:
•
For 29 V: Connect the white wire to +29V on either of the 29 VDC
terminal blocks. Connect the black wire to
−
V (GND) on the same 29
VDC terminal block.
•
For 56V: Connect the black and white wire to +56V on either of the 56
VDC terminal blocks. Connect the black wire to –V (GND) on the same
56 VDC terminal block.
13
Plug the DC power supply into an AC receptacle (AC mains).
NOTE
The AC line cord is not provided with the hardware.
14
Verify that the LEDs light.
PMP 320 Hardware Installation
LED indicators
Procedure 3-6 Cabling the CMM4 (Continued)
mounted outside, locate the PIDU in a weather-tight enclosure within 3 ft
(1 m) of the CMM4 and install a Hyperlink Technologies AL-CAT6HP-JW
surge suppressor or equivalent within 3 ft (1 m) of the PIDU.
•
PTP 500 and 600 Series bridges
: cable directly to the Gigabit
port of the EtherWAN switch. If the CMM4 is inside a building or
communication hut, install the bridge’s PIDU (Powered InDoor Unit) also
inside the building, and install a Hyperlink Technologies AL-CAT6HP-JW
surge suppressor or equivalent on the outside of the building or
communications hut at the point of cable penetration. If the CMM4 is
mounted outside, locate the PIDU in a weather-tight enclosure within 3 ft
(1 m) of the CMM4 and install a Hyperlink Technologies AL-CAT6HP-JW
surge suppressor or equivalent within 3 ft (1 m) of the PIDU.
LED indicators
The indicator LEDs color indicates position, but not the state. For example, the red Power
LED, in the left most position, lights when power is applied to the unit, but does not change
color at any point.