Connecting the ground wire
Figure 6-7 Cable connections from the surge suppressor to the CSM power injector
and the CSM
Surge Suppressor
All cables must exit
through the allocated slots
Figure 6-8 CSM 320 power injector
AC POWER
DATA & POWER DATA
OUT
IN
PORT
AC
Connecting the ground wire
The CSM must be grounded to a household ground point or to a grounding rod according to the
applicable electrical code. Equipment grounding practices vary with local building codes and
established practices of the service provider. Following is the CSM grounding procedure
as recommended by Motorola. The ground wire must be a minimum of 18 AWG, with 14 AWG
recommended for runs up to 45 m (~150 ft) and 10 AWG recommended for runs over 45 m
(~150 ft) .