Use the following procedure to connect the antenna cables to the unit. Depending upon
the type of antenna used, either two omni antennas, or one diagonal polarized antenna, the
connectors from the installed antennas must be connected to the Connectorized CSM unit
N-type connectors.
Ensure that the cable length between the CSM and the antenna connectors is 18 inches (1 ft
and 6 in).
Refer to the Chapter titled Installing Antennas for additional information regarding antenna
installation procedures.
Figure 6-5 Connectorized CSM antenna cable connector location
G1_Ccsmantennaconnid.eps
Procedure 6-6 Connecting the Antenna Cables to the Connectorized CSM when
using an Omni Antenna
1
Verify that the length between the CSM and the Omni antennas is 18 inches
apart (1 ft and 6 in). Refer to
Figure 6-5
for cable connection location on
the CSM.
2
Using a 50 ohm low loss cable with an N-type connector, connect the end of
the cable from the Omni antenna connector to the CSM N-type connector.
3
Repeat step 1 for the second Omni antenna.