Release 1.0
Configuring the CMTS
526360-001-00 Rev. B
MGBI
6-77
NUM
is the upstream port number.
0-15
is the start value.
0-15
is the end value.
Use the
no cable upstream data-backoff
command in Interface Configuration
mode to restore the upstream data-backoff default:
MOT
(config-if)#
no cable upstream
<
NUM
>
data-backoff
[
automatic
|
<
0-15
>
|
<
0-15
>
]
where:
NUM
is the upstream port number.
0-15
is the start value.
0-15
is the end value.
■
The default time value allowed by the cable interface between ranging requests
transmitted by the CM is 10000 milliseconds. If you need to adjust the time value
allowed between ranging requests, use the
cable upstream
invited-range-interval
command in Interface Configuration mode:
MOT
(config-if)#
cable upstream
<
NUM
>
invited-range-interval
<
0-30000
>
where:
NUM
is the upstream port number.
0-30000
is the number of milliseconds allowed between ranging requests.
■
Use the
cable upstream map-interval
command in Interface Configuration
mode to determine the time interval in microseconds for bandwidth maps
messages (MAP) to be used by the CM to allocate upstream time slots, as shown
in the following command example:
MOT
(config-if)#
cable upstream
<
NUM
>
map-interval
<
2000-16000
>
where:
NUM
is the upstream port number.
2000-16000
is the time interval in microseconds. The default is 4000
microseconds.
Summary of Contents for BSR 2000
Page 1: ...BSR 2000 Configuration and Management Guide 526360 001 00 Rev B Release 1 0 MGBI ...
Page 6: ... Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola Motorola ...
Page 50: ......
Page 130: ......
Page 164: ......
Page 458: ......
Page 490: ......
Page 580: ......
Page 632: ......
Page 648: ......
Page 649: ......
Page 650: ...526360 001 00 Rev B 7 06 MGBI Visit our website at www motorola com ...