Appendix 2 Link Special Register (SW) List
App
- 21
9
DE
DICA
T
E
D
INS
T
RUCT
IONS
10
T
R
OUB
L
E
S
HO
OT
IN
G
APPENDI
CES
INDEX
SW004B
Own station's CPU
status
Stores the CPU module status of the own station.
01
H
: STOP (Normal)
02
H
: STOP (Stop error is occurring)
03
H
: STOP (Continuation error is occurring)
04
H
: RUN (Normal)
05
H
: RUN (Continuation error is occurring)
06
H
: STEP-RUN
07
H
: PAUSE
0E
H
: CPU module being reset
0F
H
: CPU module initial processing in execution
SW004C
Shared group No.
Stores shared group No. of the own station.
0: No shared group setting
1 to 120: Shared group No.
SW004D
Data linking start status
(own station)
Stores the result of starting cyclic transmission with Link startup (own station)
(SB0000).
0: Normal
1 or later: Error (
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SW004F
Data linking stop status
(own station)
Stores the result of stopping cyclic transmission with Link stop (own station)
(SB0001).
0: Normal
1 or later: Error (
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SW0051
Data linking start status
(entire system)
Stores the result of starting cyclic transmission with System link startup
(SB0002).
0: Normal
1 or later: Error description of own station
(
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
SW0053
Data linking stop status
(entire system)
Stores the result of stopping cyclic transmission with System link stop
(SB0003).
0: Normal
1 or later: Error description of own station
(
(Condition)
• Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error is held.
Table App.4 Link special register (SW) list (Continued)
No.
Name
Description
Availability
Control
station
Normal
station
Link special register (SW): SW004B to SW0053