2
SYSTEM CONFIGURATION
2.1 CC-Link IE Controller Network Configurations
2.1.1 Single network system
2
- 2
1
O
V
ER
VI
E
W
2
SYST
EM
CO
NF
IG
URA
T
IO
N
3
SPECI
F
IC
A
T
IO
N
S
4
F
UNCT
IONS
5
PREP
ARA
T
IO
N AND
SET
UP
6
P
A
RAM
E
T
E
R
SET
TI
NG
7
PRO
C
ESSI
NG
T
IM
E
8
PRO
G
R
AM
M
ING
(1) When Universal model QCPU is used for control station
Up to 120 stations including one control station and 119 normal stations can be
connected. (One control station is needed for a single network.)
* 1 The receive range for other station's data varies depending on the CPU module.
Section 4.1.1 (5) Receive range for other stations' data
* 2 The receive range for other station's data varies depending on the CPU module.
Section 4.1.2 (5) Receive range for other stations' data
(2) When other than Universal model QCPU is used for control station
Up to 64 stations including one control station and 63 normal stations can be
connected. (One control station is needed for a single network.)
* 1 The receive range for other station's data varies depending on the CPU module.
Section 4.1.1 (5) Receive range for other stations' data
* 2 The receive range for other station's data varies depending on the CPU module.
Section 4.1.2 (5) Receive range for other stations' data
* 3 A station with a Basic model QCPU or safety CPU operates as a normal station. (It cannot be set to
a control station.)
Table 2.1 When Universal model QCPU is used for control station
Item
Basic model QCPU
Safety CPU
High Performance
model QCPU
Process CPU
Redundant CPU
Universal model
QCPU
Network type
Normal station
Control station and
normal station
Station No.
Station No.1 to 64
Station No.1 to 120
Link device
range
Link relay (LB)
*1
LB0 to 3FFF
LB0 to 7FFF
Link register (LW)
*1
LW0 to 3FFF
LW0 to 1FFFF
Link input (LY)
*2
LX0 to 1FFF
Link output (LY)
LY0 to 1FFF
Link special relay (SB)
SB0 to 1FF
Link special register (SW)
SW0 to 1FF
Table 2.2 When other than Universal model QCPU is used for control station
Item
Basic model QCPU
Safety CPU
High Performance
model QCPU
Process CPU
Redundant CPU
Universal model
QCPU
Network type
Normal station
*3
Control station and
normal station
Normal station
Station No.
Station No.1 to 64
Link device
range
Link relay (LB)
*1
LB0 to 3FFF
LB0 to 7FFF
Link register (LW)
*1
LW0 to 3FFF
LW0 to 1FFFF
Link input (LY)
*2
LX0 to 1FFF
Link output (LY)
LY0 to 1FFF
Link special relay (SB)
SB0 to 1FF
Link special register (SW)
SW0 to 1FF
Summary of Contents for QJ71GP21-SX
Page 1: ......
Page 2: ......
Page 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Page 649: ......
Page 650: ......