9.12 J(P).ZNRD
This instruction reads data from devices of a programmable controller on another station.
(In units of words)
* 1 T, C, D or W can be used.
(1) Setting data
* 1 Local devices and file registers for each program cannot be used as devices in setting data.
* 2 In addition to the setting data, the ZNRD instruction is executed using the following fixed values.
Channel used by own station: Channel 1
Arrival monitoring time (monitoring time until instruction completion): 10 seconds
Number of resends for arrival monitoring timeout: 5 times
Table 9.65 Devices available for setting data
Setting
data
Available devices
Internal device
(System, User)
File
register
Link direct device
J \
Intelligent function
module device
U \G
Index register
Zn
Constant
Others
Bit
Word
Bit
Word
K, H
$
n1
—
—
(S1)
—
*1
—
—
—
—
(D1)
—
—
—
—
n2
—
—
(D2)
—
—
—
Figure 9.90 Instruction format
Table 9.66 Setting data
Setting data
*1*2
Description
Data type
Jn
Network No. of the target station (1 to 239)
Binary 16 bits
n1
Target station No. (1 to 64)
(S1)
Target station's start device where data to be read are stored
Device name
(D1)
The own station's start device where readout data will be stored
(A contiguous area for the read data length is required.)
n2
Read data length
When the target station is Q/QnA/AnUCPU: 1 to 230 words
When the target station is other than Q/QnA/AnUCPU: 1 to 32
words
Binary 16 bits
(D2)
The own station's device that is turned on for one scan upon
completion of the instruction
(D2)+1 also turns ON if the instruction execution has failed.
Bit
J.ZNRD
Jn
(S1)
(D1)
n2
(D2)
JP.ZNRD
Jn
(S1)
n1
n1
(D1)
n2
(D2)
J.ZNRD
Start contact
[Instruction format]
[Execution condition]
[Instruction symbol]
JP.ZNRD
Start contact
Summary of Contents for QJ71GP21-SX
Page 1: ......
Page 2: ......
Page 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Page 649: ......
Page 650: ......