9
- 12
9.3 JP/GP. READ
9
DEDICATED INSTRUCTIONS
(2) Control data
Table 9.8 Control data
Device
Item
Setting data
Setting range
Setting
side *1
(S1)+0
Error completion
type
1) Error completion type (bit 7)
Specify the clock data setup status for error completion.
0: Clock data at the time of error completion is not set in the area
starting from (S1)+11.
1: Clock data at the time of error completion is set in the area
starting from (S1)+11.
0001
H
0081
H
User
(S1)+1
Completion status
The instruction completion status is stored.
0: Normal
Other than 0: Error (
—
System
(S1)+2
Channel used by
own station
*2
Specify the channel used by the own station. (
(1) When executing multiple link dedicated instructions at the same
time)
1 to 10
(1 to 8 when the
own station is a
safety CPU)
User
(S1)+3
Target station's
CPU type
Specify the type of the target station CPU.
0000
H
03D0
H
to 03D3
H
03E0
H
to 03E3
H
03FF
H
User
Setting value
Description
0000
H
Target station CPU, control CPU, own system CPU
(Specified data are the same as "03FF
H
".)
03D0
H
Control system CPU
03D1
H
Standby system CPU
03D2
H
System A CPU
03D3
H
System B CPU
03E0
H
• Target station CPU (single CPU system)
• Multi-CPU No.1
03E1
H
Multi-CPU No.2
03E2
H
Multi-CPU No.3
03E3
H
Multi-CPU No.4
03FF
H
Target station CPU, control CPU, own system CPU
When the instruction is executed with control system CPU (03D0
H
) or
standby system CPU (03D1
H
) specified, if system switching occurs at
the target station, the instruction execution may fail. (Error code:
4244
H
, 4248
H
)
If the instruction has failed with the above error, execute it again.
(S1)+4
Target station
network No.
Specify the network No. of the target station.
1 to 239: Network No.
254: Specify this when 254 has been set in Jn.
1 to 239
254
User
(S1)+5
Target station No.
Specify the station No. of the target station.
When own station is Universal model QCPU: 1 to 120
When own station is other than Universal model QCPUs: 1 to 64
1 to 120
User
(S1)+6
—
Unused
0
User
(S1)+7
Number of resends
1) For instruction execution
Specify the number of times the instruction is to be resent when it
is not completed within the monitoring time specified in (S1)+8.
0 to 15
User
2) At instruction completion
The number of resends executed (result) is stored.
—
System
b15
0
0
1
1)
b7
b0
to
to
Summary of Contents for QJ71GP21-SX
Page 1: ......
Page 2: ......
Page 644: ...App 94 Appendix 6 External Dimensions Appendix 6 2 QJ71GP21S SX APPENDICES Memo ...
Page 649: ......
Page 650: ......