APPENDICES
Appendix 1 Link Special Relay (SB) List
App
- 15
9
DE
DICA
T
E
D
INS
T
RUCT
IONS
10
T
R
OUB
L
E
S
HO
OT
IN
G
APPENDI
CES
INDEX
SB01B0
Each station's CPU type
information
Stores CPU type information on the stations (including the own station).
OFF: No Basic model QCPU or safety CPU
ON: Station of Basic model QCPU or safety CPU exists.
If any station has a Basic model QCPU or safety CPU, each station's status
can be checked by Each station's CPU type information (SW01B0 to
SW01B7).
SB01C0
Redundant system
information
Stores redundant system information on the stations (including the own
station).
OFF: No redundant system station
ON: Redundant system station exists.
If any station is configured as a redundant system, each station's status can be
checked by Redundant function support information (SW01C0 to SW01C7).
SB01D0
Redundant system
status (1)
Stores the CPU operation mode status of the stations (including the own
station).
OFF: No separate-mode station (including single systems)
ON: Separate-mode station exists.
If any station is in separate mode, each station's status can be checked by
Redundant system status (1) (SW01D0 to SW01D7).
(Condition)
Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
SB01E0
Redundant system
status (2)
Stores the pairing setting status of the stations (including the own station).
OFF: No pairing-set station
ON: Pairing-set station exists.
If any station has a pairing setting, each station's status can be checked by
Redundant system status (2) (SW01E0 to SW01E7).
(Condition)
Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
SB01F0
Redundant system
status (3)
Stores the CPU operating status (control/standby system) of the stations
(including the own station).
OFF: No standby system CPU station (including single systems)
ON: Station of standby system CPU exists.
If a station has a standby system CPU, each station's status can be checked
by Redundant system status (3) (SW01F0 to SW01F7).
(Condition)
Valid when Baton pass status (own station) (SB0047) is OFF.
When Baton pass status (own station) (SB0047) is turned ON (error), data
prior to error are held.
Table App.2 Link special relay (SB) list (Continued)
No.
Name
Description
Availability
Control
station
Normal
station
Link special relay (SB): SB01B0 to SB01F0