3Installing the option devices
Installing the solenoid valve set 3-60
(2) RH-12FH/20FH series
Fig.3-2 : Solenoid valve installation procedures (RH-12FH/20FH)
The installation procedure is detailed below.
1) Remove the screws fixing the No. 2 arm cover U, and remove the No. 2 arm cover U.
2) Fix the solenoid valve to the plate in the position indicated in
.Place it so that the solenoid valve's
primary piping connection joints (P, R ports) are located on the upper side, and fix it securely using the M4
screws included (tightening torque: 1.39 to 1.89N ・ m).
3) Connect the connector (GR1, GR2) of solenoid valve with connector of robot arm side (GR1, GR2). Connect
with the same names. The hand output signal cables of the robot arm side are located close to where the
solenoid valve is installed and are tied up with cable tie. Pull out and connect them to the connectors. Fix
the connectors so that they will not move along with the robot movement. (Refer to
tor protection when the option devices are installed"
4) Connect the primary piping air hose (φ6). The air hoses are located close to where the solenoid valve is
installed and are tied up with cable tie. Cut the cable tie and connect them. Of the two air hoses, connect
the one marked “AIR IN” to the solenoid valve's P port, and the one marked “RETURN” to the R port.
Note) When connecting the RETURN air hose, be sure to remove the dust cap attached at the RETURN
joint on the robot base section. If the cap is not removed, exhaust air pressure will increase and
the solenoid valve may not operate properly.By connecting the exhaust air hose (φ6: customer
1
3
5
7
2
4
6
8
Install to inside the No. 2 arm
cover U
No. 2 arm cover U
Solenoid valve
Fix to plate.
primary piping air hose (
φ
6)
(P port)
Hand output signal connection
connectors (GR1, GR2)
Connect to the GR1 and GR2
connectors of the robot side.
Fixing screws (M4 x 8), four screws
- left and right
(included in the solenoid valve set)
Items for customer to prepare
・
A hexagon wrench (M4 screws)
・
Air hose for secondary piping (
φ
6)
Solenoid valve exhaust hose (
φ
6)
(R port)
Note) When connecting this air hose, be
sure to remove the dust cap attached on
the robot base section.
Secondary piping connection joint (
φ
6)
(A, B ports)
A port: From the left side in order 1, 3, 5, 7
B port: From the left side in order 2, 4, 6, 8
Primary piping connection joint (
φ
6)
(P port)
Solenoid valve exhaust joint (
φ
6)
(R port)
Hand output signal connection
cables (GR1, GR2)
Base section
Primary piping connection joint
(
φ
6) (upper side: AIR IN)
Solenoid valve exhaust joint (
φ
6)
(lower side: RETURN)
For the elbow coupling addition
KJL06-99 *SUS street elbow
(SMC Corp.)