252
4 APPLICABLE FUNCTIONS
4.6 Drive recorder
Servo parameter [A]
Servo
parameter
Symbol
Name
Outline
PF80.0
DRMC
Drive recorder - Operation mode
selection
Select the operation mode of drive recorder.
0: Automatic setting mode (initial value)
1: Manual setting mode
PF80.2-3
DRMC
Drive recorder - Sampling cycle
selection
Set the sampling cycle.
00: Automatic (250
μ
s) (initial value)
05: 250
μ
s
06: 500
μ
s
07: 1 ms
08: 2 ms
09: 4 ms
0A: 8 ms
0B: 16 ms
0C: 32 ms
0D: 64 ms
0E: 128 ms
0F: 256 ms
10: 512 ms
11: 1.024 s
PF81.0
DRMS
Drive recorder - Sampling start
selection
Select to start sampling in manual setting mode.
0: Stop sampling (initial value)
1: Start a single sampling
2: Start a consecutive sampling
PF82.0
DRTM
Drive recorder - Trigger mode
selection
Select the trigger mode.
0: Alarm trigger (initial value)
1: Analog trigger/digital trigger
PF82.1
DRTM
Drive recorder - Trigger binding
condition selection
Select the binding condition of the trigger.
0: Disabled (initial value)
1: Logical AND of trigger signals
2: Logical OR of trigger signals
PF82.2
DRTM
Drive recorder - Trigger operation
selection 1
Select whether sampling starts when the channel set in [Pr. PF84.0-1 Drive recorder
- Trigger channel selection 1] exceeds the set trigger level (rising) or starts when it
falls below the set trigger level (falling).
0: Rising (initial value)
1: Falling
PF82.3
DRTM
Drive recorder - Trigger operation
selection 2
Select whether sampling starts when the channel set in [Pr. PF84.2-3 Drive recorder
- Trigger channel selection 2] exceeds the set trigger level (rising) or starts when it
falls below the set trigger level (falling).
0: Rising (initial value)
1: Falling
PF84.0-1
DRTC
Drive recorder - Trigger channel
selection 1
Set trigger channel No. 1.
Initial value: 01h (Analog channel 1)
PF84.2-3
DRTC
Drive recorder - Trigger channel
selection 2
Set trigger channel No. 2.
Initial value: 81h (Digital channel 1)
PF84.4-5
DRTC
Drive recorder - Trigger position
setting
For the total sampling time, set the trigger position in hexadecimal from 0 to 100 %.
Initial value: 5Ah (90 [%])
PF85
DRTL1
Drive recorder - Trigger level
setting 1
Set the trigger level of [Pr. PF84.0-1 Drive recorder - Trigger channel selection 1] in
decimal.
Initial value: 0
PF86
DRTL2
Drive recorder - Trigger level
setting 2
Set the trigger level of [Pr. PF84.2-3 Drive recorder - Trigger channel selection 2] in
decimal.
Initial value: 0
PF87.0-2
DRAC1
Drive recorder - Analog channel 1
selection
Set the data to be assigned to analog channel 1.
Initial value: 201h (Servo motor speed +)
PF87.4-6
DRAC1
Drive recorder - Analog channel 2
selection
Set the data to be assigned to analog channel 2.
Initial value: 002h (Torque/instantaneous torque)
PF88.0-2
DRAC2
Drive recorder - Analog channel 3
selection
Set the data to be assigned to analog channel 3.
Initial value: 003h (Current command)
PF88.4-6
DRAC2
Drive recorder - Analog channel 4
selection
Set the data to be assigned to analog channel 4.
Initial value: 204h (Droop pulse (1 pulse unit) +)
PF89.0-2
DRAC3
Drive recorder - Analog channel 5
selection
Set the data to be assigned to analog channel 5.
Initial value: 205h (Speed command + )