3 BASIC FUNCTION
3.18 Acceleration/deceleration function
147
3
Acceleration/deceleration [G] [WG]
Acceleration/deceleration are available on servo amplifiers with firmware version A5 or later.
Acceleration/deceleration is performed in accordance with the specified acceleration/deceleration [command unit/s
2
]. Unlike
the acceleration/deceleration time constants, acceleration/deceleration can be performed independent of the rated speed of
the servo motor.
The control mode influences whether the acceleration/deceleration is set in the servo parameters, objects, or other settable
areas.
Setting example
To accelerate at 0.5 [s] from 0 [command unit/s] to 1500 [command unit/s], set 3000 [command unit/s
2
] for the acceleration.
To decelerate at 2 [s] from 1500 [command unit/s] to 0 [command unit/s], set 750 [command unit/s
2
] for the deceleration.
Precautions
• The servo parameter for setting the acceleration/deceleration data varies depending on the unit selected in [Pr. PT01.1
Speed/acceleration/deceleration unit selection]. However, the same object is used for setting the acceleration/deceleration
data regardless of the unit selected. Refer to [Pr. PT01.1] for details. For the precautions for each acceleration/deceleration
data, refer to the setting servo parameters and objects.
Servo motor speed
Acceleration
Time [s]
Time [s]
Deceleration
Speed [command unit/s]
Acceleration/deceleration
[command unit/s
2
]
Acceleration time =
Servo motor speed
Acceleration
Deceleration time =
Servo motor speed
Deceleration