4 APPLICABLE FUNCTIONS
4.6 Drive recorder
249
4
■
Analog channel
Setting value
Data type
Unit
Category
000
No assigned function
001
Servo motor speed
1 r/min
16-bit data
002
Torque/instantaneous torque
0.1 %
003
Current command
0.1 %
005
Command pulse frequency (speed unit)
1 r/min
007
Droop pulses (1 pulse unit)
1 pulse
008
Speed command
1 r/min
009
Bus voltage
1 V
00C
Effective load ratio
0.1 %
00D
Regenerative load ratio
0.1 %
00E
Position within one-revolution
16 pulse
00F
ABS counter
1 rev
010
Load to motor inertia ratio
0.01 times
011
Disturbance torque
0.1 %
012
Overload alarm margin
0.1 %
014
Settling time
1 ms
015
Overshoot amount
1 pulse
01C
Load-side encoder droop pulses (1 pulse unit)
1 pulse
01E
Motor-side/load-side position deviation (1 pulse unit)
1 pulse
020
Motor-side/load-side speed deviation
1 r/min
021
Servo motor speed (0.1 r/min unit)
0.1 r/min
022
Command pulse frequency (0.1 r/min speed unit)
0.1 r/min
023
Speed command (0.1 r/min unit)
0.1 r/min
024
Torque command
0.1 %
025
Speed limit value
1 r/min
026
Speed limit value (0.1 r/min unit)
0.1 r/min
035
Internal temperature of encoder
1 °C
03B
Load-side encoder information 1
16 pulse
03C
Load-side encoder information 2
1 rev
049
Operation mode
1LSB
04C
U-phase current feedback (unit of the rated current)
0.1 %
04D
V-phase current feedback (unit of the rated current)
0.1 %
04E
W-phase current feedback (unit of the rated current)
0.1 %
201
Servo motor speed +
0.1 r/min
32-bit data
202
Command pulse fre
kpulse/s
203
Command pulse frequency (speed unit) +
0.1 r/min
204
Droop pulses (1 pulse unit) +
1 pulse
205
Speed c
0.1 r/min
206
Position within one-revo
1 pulse
207
Load-side encoder information 1 +
1 pulse
208
Load-side encoder information 2 +
1 pulse
209
Load-side droop
1 pulse
20B
Feedback po
1 pulse
20C
Excessive error alarm
1 pulse
218
Droop pulses (100 pulse units) +
100 pulse
219
Load-side encoder droop pulses (100 pulses unit) +
100 pulse
21A
Excessive error alarm margin (100 pulse units) +
100 pulse
21B
Droop pulses (model position deviation) +
1 pulse
220
Speed command 2+
0.1 r/min
23C
Droop pulses (command unit) +
1 pulse