4 APPLICABLE FUNCTIONS
4.8 Software position limit [G] [WG]
267
4
■
When [Pr. PT01.2] is set to "2" (degree)
Set [Pr. PT17] as the starting point and [Pr. PT15] as the ending point.
The moving part can move from "-" to "+" in the CCW direction.
Set servo parameters as follows to specify moving range A.
• [Pr. PT17] = 315.000 degrees
• [Pr. PT15] = 90.000 degrees
Set servo parameters as follows to specify moving range B.
• [Pr. PT17] = 90.000 degrees
• [Pr. PT15] = 315.000 degrees
The setting range is 0 to 359.999 degrees. If a value out of the setting range is set, the value will be converted as shown in the
table below. The values of the movable range are the values after conversion.
When the moving part moves into the range of the software position limit from outside the range, the moving direction is
determined by which part of the non-movable area the moving part is in as shown in the following figure. The moving part can
move only in the direction with the shortest distance to the movable area.
Ex.
When [Pr. PT17] is set to 315.000 degrees and [Pr. PT15] is set to 90.000 degrees:
Setting value
After conversion
360.000 to 2147483.647 degrees
The remainder obtained by dividing the setting value by 360.000
-0.001 to -359.999 degrees
The value obtained by adding 360.000 to the setting value
-360.000 to -2147483.648 degrees
The value obtained by adding 360.000 to the remainder after dividing the setting value by 360.000
CCW
0 [degree]
90 [degree]
315 [degree]
Moving range A
Moving range B
0 [degree]
90 [degree]
315 [degree]
0 [degree]
90 [degree]
315 [degree]
225 [degree]
135 [degree]
Movable area
Movable area
Non-movable area
Non-movable area
The moving part can move.