8 COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC AC SERVO PROTOCOL) [A]
8.5 Detailed explanations of commands
Servo parameter
Specifying a servo parameter group
To read or write servo parameter setting values or other data, specify the group of servo parameters to be operated in
advance. Write data to the servo amplifier as follows to specify the servo parameter group.
Reading a servo parameter group
The set servo parameter group can be read from the slave station.
■
Transmission
Transmit the command [0] [4] + data No. [0] [1].
■
Return
The slave station returns the set servo parameter group.
Reading a symbol
The symbol of servo parameters can be read. Specify a servo parameter group in advance.
■
Transmission
Transmit the command [0] [8] and the data No. [0] [1] to [F] [F] corresponding to the servo parameter No.
The data No. is represented in hexadecimal. The decimal converted from the data No. value corresponds to the servo
parameter No.
■
Return
The slave station returns the symbol of the requested servo parameter.
Command
Data No.
Transmission
data
Servo parameter group
[8] [5]
[0] [0]
0000
Basic setting servo parameters ([Pr. PA_ _ ])
0001
Gain/filter servo parameters ([Pr. PB_ _ ])
0002
Extension setting servo parameters ([Pr. PC_ _ ])
0003
I/O setting servo parameters ([Pr. PD_ _ ])
0004
Extension setting 2 servo parameters ([Pr. PE_ _ ])
0005
Extension setting 3 servo parameters ([Pr. PF_ _ ])
000B
Motor extension setting servo parameters ([Pr. PL_ _ ])
0 0
Servo parameter group
00: Basic setting servo parameters ([Pr. PA_ _ ])
01: Gain/filter servo parameters ([Pr. PB_ _ ])
02: Extension setting servo parameters ([Pr. PC_ _ ])
03: I/O setting servo parameters ([Pr. PD_ _ ])
04: Extension setting 2 servo parameters ([Pr. PE_ _ ])
05: Extension setting 3 servo parameters ([Pr. PF_ _ ])
0B: Motor extension setting servo parameters ([Pr. PL_ _ ])
0 0 0
Symbol characters (9 digits)