5 MONITORING
5.3 Analog monitor [G] [WG]
325
5
Setting details
When using a linear servo motor, the terms below have the following meanings.
CCW direction
→
Positive direction
CW direction
→
Negative direction
Torque
→
Thrust
In the factory setting, the servo motor speed is outputted to MO1 (analog monitor 1), and the torque is outputted to MO2
(analog monitor 2). However, by setting [Pr. PC09 Analog monitor 1 output] and [Pr. PC10 Analog monitor 2 output], the
contents can be changed as shown in the following table.
Refer to the following for a description of each signal and the points detected.
Page 306 Explanation of monitor signals
Setting
value
Output item
Description
00
Servo motor speed
01
Torque/Thrust
02
Servo motor speed
03
Torque/Thrust
04
Current command
0
8 [V]
-8 [V]
CCW direction
Maximum speed
Maximum speed
CW direction
0
8 [V]
-8 [V]
Power running in CCW direction
Maximum torque
Maximum torque
Power running in CW direction
0
8 [V]
CW direction
CCW direction
Maximum speed
Maximum speed
0
8 [V]
Power running in
CW direction
Power running in
CCW direction
Maximum torque
Maximum torque
0
8 [V]
-8 [V]
CCW direction
Maximum current
command
(maximum torque
command)
Maximum current
command
(maximum torque
command)
CW direction