334
6 FUNCTIONAL SAFETY
6.1 Functions and configuration
6
FUNCTIONAL SAFETY
6.1
Functions and configuration
Outline
For the compatible servo amplifiers and firmware versions, refer to "Functional safety" in the User's Manual (Introduction).
Features of functions
■
When using the safety sub-functions via a network
For the MR-J5-G-RJ, the safety sub-function functions can be used via a network. This helps to minimize wiring.
For the available safety sub-functions and safety levels, refer to "Functional safety" in the User's Manual (Introduction).
The compatible controller is as follows.
■
When using the safety sub-functions by wiring to the CN8 connector (safety sub-function
control by input device)
The safety sub-functions can be used by using an input device.
Outline of safety sub-functions
The functions that can be used for functional safety are as follows.
Category
Model
Motion module
RD78G(H)
Function
Description
Detailed explanation
STO (Safe torque off)
This function electrically shuts off the servo motor driving energy with input signals from
external devices (shut-off by the secondary-side output). This is equivalent to the stop
category 0 of IEC/EN 60204-1.
SS1 (Safe stop 1)
This function starts deceleration with input signals from external devices. After the specified
time to confirm the motor stop, the STO function is executed (SS1). This is equivalent to the
stop category 1 of IEC/EN 60204-1.
SS2 (Safe stop 2)
This function starts deceleration with input signals from external devices. After the specified
time to confirm the motor stop, the SOS function is executed (SS2). This is equivalent to the
stop category 2 of IEC/EN 60204-1.
SOS (Safe operating stop)
This function monitors whether the servo motor stops within the prescribed range. Energy is
supplied to the servo motor.
SLS (Safely-limited speed)
This function monitors whether the speed is within the prescribed speed limit. If the speed
exceeds the specified speed limit, the STO will shut off energy.
SSM (Safe speed monitor)
This function outputs signals when the servo motor speed is below the prescribed speed.
SBC (Safe brake control)
This function outputs signals for controlling the external brake.
SDI (Safe direction)
This function monitors whether the servo motor travels in the specified direction. If the servo
motor travels in a direction different from the specified direction, the STO will shut off energy.
SLI (Safely-limited increment)
This function monitors whether the travel distance of the servo motor is within the specified
range. If the travel distance of the servo motor exceeds the specified range, the STO will
shut off energy.
SLT (Safely-limited torque)
This function monitors whether the torque is below the specified torque. If the torque
exceeds the specified torque, the STO will shut off energy.
Status monitor (SM: Status
monitor)
This function outputs the statuses of the safety sub-functions as signals. This is a function
designed specifically for the safety sub-functions and differs from the function defined in
IEC/EN 61800-5-2.