122
3 BASIC FUNCTION
3.14 Alarm function
Operation status at warning occurrence [G] [WG]
The following shows the status of servo amplifiers at a warning occurrence.
Operation status at warning occurrence [A]
The following shows the status of servo amplifiers at a warning occurrence.
Status
Reference
The No. of the warning that has occurred is shown on the 7-segment LED.
Refer to "Switch setting and display of the servo amplifier" in
the User's Manual (Introduction).
The operation is continued. However, when a warning that stops the servo motor occurs, the
servo motor is stopped using the method determined by the warning.
Page 125 Stop method at occurrence of alarms/warnings
Output device signals such as WNG (Warning) are turned off. In addition, at an occurrence of
a warning to stop the servo motor, WNGSTOP (Motor stop warning) is turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2 or via
a network.
Page 123 Alarm history [G] [WG]
Status
Reference
The No. of the warning that has occurred is shown on the 7-segment LED.
The operation is continued. However, when a warning that stops the servo motor occurs, the
servo motor is stopped using the method determined by the warning.
Page 125 Stop method at occurrence of alarms/warnings
Output device signals such as WNG (Warning), ALMWNG (Malfunction/Warning) are turned
off. In addition, at an occurrence of a warning to stop the servo motor, WNGSTOP (Motor stop
warning) is turned off.
The occurrence status of alarms and warnings can be monitored with MR Configurator2.