50
2 CONTROL MODE
2.1 Control mode [G] [WG]
Operation example of the CiA 402-type Homing method
The following shows an operation example of the homing in the CiA 402-type Homing method.
■
Method 1 (Homing on negative limit switch and index pulse) and Method 2 (Homing on
positive limit switch and index pulse)
The following figure shows the operation of Homing method 2. The homing direction of Homing method 1 is opposite to that of
Homing method 2.
• When homing is started from the stroke end
*1 This cannot be used with the software limit.
Statusword bit 10
Target reached
ON
OFF
ON
OFF
Statusword bit 12
Homing attained
ON
OFF
Controlword bit 4
Homing operation start
ON
OFF
0 r/min
Servo motor speed
3 ms or shorter
Homing speed
Home position
shift distance
*1
Homing position data
Acceleration time constant
Stroke end
Creep speed
Reverse
rotation
Z-phase
Forward
rotation
0 r/min
ON
OFF
Homing direction
Homing start position
Servo motor speed
Reverse
rotation
Stroke end
*1
Home position
shift distance
Z-phase
Homing position data
Creep speed
Forward
rotation