3 BASIC FUNCTION
3.4 Stroke limit function [G] [WG]
93
3
Setting methods of functions
Refer to the following table, and make the appropriate settings for the system configuration.
When wiring the limit switch to the servo amplifier
Refer to the system configuration example shown in this section, and input the signal of the limit switch to the servo amplifier.
Set [Pr. PD41.3 Sensor input method selection] to "0" to use the initial setting (Input from the servo amplifier (LSP/LSN/
DOG)). Set the limit switch installed in CCW or the positive direction to LSP, and set the limit switch installed in CW or the
negative direction to LSN. In the initial setting, LSP is assigned to the CN3-2 pin, and LSN is assigned to the CN3-12 pin.
The information from the stroke end that is transmitted to the controller changes depending on the setting in [Pr. PA14 Travel
direction selection].
When [Pr. PA14 Travel direction selection] is set to "0" (rotating in CCW or traveling in the positive direction) with an
increasing positioning address.
When [Pr. PA14 Travel direction selection] is set to "1" (rotating in CW or traveling in the negative direction) with an increasing
positioning address.
Item
Reference
When wiring the limit switch to the servo amplifier
Page 93 When wiring the limit switch to the servo amplifier
When wiring the limit switch to equipment other than the servo amplifier
Page 95 When wiring the limit switch to equipment other than the servo
When setting the movable range with the position data
Page 95 When setting the movable range with the position data
When the movable range is not limited
Page 95 When the movable range is not limited
Signal names of the stroke end
Signal names of the corresponding stroke limits
Symbol
Signal name
Symbol
Signal name
LSP
Forward rotation stroke end
FLS
Upper stroke limit
LSN
Reverse rotation stroke end
RLS
Lower stroke limit
Signal names of the stroke end
Signal names of the corresponding stroke limits
Symbol
Signal name
Symbol
Signal name
LSP
Forward rotation stroke end
RLS
Lower stroke limit
LSN
Reverse rotation stroke end
FLS
Upper stroke limit