*1 Available on servo amplifiers with firmware version B2 or later.
Conditions for erasing absolute position data
For an incremental system, the absolute position data is erased in the following situations:
• If homing is not being executed.
• If homing is in progress.
• If [AL. 069 Command error] occurs.
For an absolute position detection system, the absolute position data is erased in the following situations:
• If homing is not being executed.
• If homing is in progress.
• If [AL. 069 Command error] occurs.
• If [AL. 025 Absolute position erased] or [AL. 0E3 Absolute position counter warning] occurs.
• If the electronic gear ([Pr. PA06] or [Pr. PA07]) is changed.
• If the setting of [Pr. PA03.0 Absolute position detection system selection] is changed.
• If [Pr. PA14 Travel direction selection] is changed.
• If [Pr. PA01.1 Operation mode] is changed.
24
Homing without index pulse
Forward
rotation
Although this type is the same as the dog cradle type homing, the stop position
is not on the Z-phase. Starting from the front end of the dog, the position is
shifted by the travel distance after proximity dog and the home position shift
distance. The position after the shifts is set as the home position.
27
Homing without index pulse
Reverse
rotation
This is the same as the dog type front end reference homing.
28
Homing without index pulse
Reverse
rotation
Although this type is the same as the dog cradle type homing, the stop position
is not on the Z-phase. Starting from the front end of the dog, the position is
shifted by the travel distance after proximity dog and the home position shift
distance. The position after the shifts is set as the home position.
33
Homing on index pulse
Reverse
rotation
Although this type is the same as the dogless Z-phase reference homing, the
creep speed is applied as the movement start speed.
34
Homing on index pulse
Forward
rotation
Although this type is the same as the dogless Z-phase reference homing, the
creep speed is applied as the movement start speed.
35
Homing on current position
The current position is set as the home position. This type can be executed even
when the servo amplifier is not in the Operational enabled state.
37
Homing on current position
The current position is set as the home position. This type can be executed even
when the servo amplifier is not in the Operational enabled state.
Method No.
Homing methods
Rotation
direction
Description