4 APPLICABLE FUNCTIONS
4.6 Drive recorder
253
4
*1 Refer to the following for setting values.
Page 254 Trigger channel selection
*2 Refer to the following for setting values.
*3 Refer to the following for setting values.
PF89.4-6
DRAC3
Drive recorder - Analog channel 6
selection
Set the data to be assigned to analog channel 6.
Initial value: 009h (Bus voltage)
PF90.0-2
DRAC4
Drive recorder - Analog channel 7
selection
Set the data to be assigned to analog channel 7.
Initial value: 00Ch (Effective load ratio)
PF91.0-3
DRDC1
Drive recorder - Digital channel 1
selection
Set the data to be assigned to digital channel 1.
Initial value: 0000h (SON)
PF91.4-7
DRDC1
Drive recorder - Digital channel 2
selection
Set the data to be assigned to digital channel 2.
Initial value: 0012h (EM2/EM1)
PF92.0-3
DRDC2
Drive recorder - Digital channel 3
selection
Set the data to be assigned to digital channel 3.
Initial value: 8010h (ALM2)
PF92.4-7
DRDC2
Drive recorder - Digital channel 4
selection
Set the data to be assigned to digital channel 4.
Initial value: 8005h (INP)
PF93.0-3
DRDC3
Drive recorder - Digital channel 5
selection
Set the data to be assigned to digital channel 5.
Initial value: 800Ah (MBR)
PF93.4-7
DRDC3
Drive recorder - Digital channel 6
selection
Set the data to be assigned to digital channel 6.
Initial value: 8000h (RD)
PF94.0-3
DRDC4
Drive recorder - Digital channel 7
selection
Set the data to be assigned to digital channel 7.
Initial value: 8015h (STO)
PF94.4-7
DRDC4
Drive recorder - Digital channel 8
selection
Set the data to be assigned to digital channel 8.
Initial value: 801Dh (IPF)
PF95.0
*DRCLR
Drive recorder - Drive recorder
clear history selection
When enabled is selected, the drive recorder history will be cleared at either the next
power cycle, at software reset, or at controller reset.
0: Disabled (initial value)
1: Enabled
PF21
DRT
Drive recorder switching time
setting
Set the drive recorder switching time.
When the USB communication is disconnected during the use of the graph function,
the function will be switched to the drive recorder function after the time set in this
servo parameter has passed.
Initial value: 0 (switched after 10 s)
PA23.0-1
DRAT
Alarm detail number setting
To execute the trigger with a desired alarm detail number, set [Pr. PF80.0 Drive
recorder - Operation mode selection] = "0" (automatic setting mode) or [Pr. PF82.0
Drive recorder - Trigger mode selection] = "0" (alarm trigger) in [Pr. PF80.0] = "1"
(manual setting mode).
At "00", only the optional alarm number setting will be enabled.
Initial value: 00h
PA23.2-4
DRAT
Alarm number setting
To execute the trigger with a desired alarm number, set [Pr. PF80.0 Drive recorder -
Operation mode selection] = "0" (automatic setting mode) or [Pr. PF82.0 Drive
recorder - Trigger mode selection] = "0" (alarm trigger) in [Pr. PF80.0] = "1" (manual
setting mode).
When "000" is set, arbitrary alarm trigger of the drive recorder will be disabled.
Initial value: 000h
Servo
parameter
Symbol
Name
Outline